Extended System-Level Command Functions






Class Series Programmer’s Manual

83

(SA) SOP Adjust – This command sets the start of print (SOP) location, relative to the top of
form. See <STX>O for command details. The

EX2

accepts this command for backward

compatibility only, limited in range (28-228). The <STX>KcQQQ response shows the Row
Adjust Fine Tune (RF) equivalent value.



(SC) Scalable Cache
–
This command sets the number of 1K blocks allocated for the scaleable
font engine. Available memory dependent upon model; see Appendix K. (For non-display models
see the <STX>KS command.)



(SE) SOP Emulation –
This command enables the <STX>O and <STX>f print positioning
commands to allow backward compatibility with label formats designed for other printers.



(SF) Save As Filename – This command, which may be sent separately or included as the last
command in an <STX>Kc command string, saves the effective printer configuration to a file in
Flash memory with a .dcm file extension.



(SG) Sensor Gain Value –
This command sets the control of the voltage to the LED emitter of
the Media Sensor.



(SH) Scalable Heap –
This command sets a working “scratch pad space” in DRAM for scalable
font construction.



(Sl) Security Lock –
This command provides the ability to password-protect all printer settings
made through the User Interface, as follows:


Value

Security Function

Nxxxx

Where xxxx is the current password, this disables Menu protection.

Yxxxx

Where xxxx is a new password, this enables Menu protection and sets a new password.

Txxxx

Where xxxx is a new password, this enables Menu protection, disables the User
Interface Test Button functions, and sets a new password.

Table 5-9: Security Lock Command