3u / 3ub – EBARA 3U, 3UB User Manual

Page 9

Advertising
background image

EBARA End Suction Centrifugal

3U / 3UB

Operating, Installation, and Maintenance

EBARA

Fluid Handling

www.pumpsebara.com

9

(t) 803 327-5005 • (f) 803 327-5097

rev. 02/09

3U / 3UB Installation Instructions

Mounting the Assembly

Do not operate the pump unless the assembly is securely and properly mounted.

Misalignment of the motor/pump assembly or not having the assembly reasonably level may cause pump vibration,
noisy operation, fluid leaks, or air leaks and air locks in the suction pipe.

1. Place the motor/pump assembly in its intended operating position.

2. Level the pump through the centerline of the motor/pump assembly suction port.

Initial Operation

Make certain the motor is not connected to a power source until the motor is properly assembled and mounted.
Serious personal injury or damage to the motor/pump assembly could occur if the motor is activated improperly.

Only certified electricians should make electrical connections.

1. Prime the pump by adding fluid to the volute case through the top plug.To properly prime the pump, venting

may be required.

2. Check the nameplate on the motor to determine the correct wiring procedure for your intended power source

and if the motor is single or three phase. Connect the motor to a power source by following the wiring procedure
on the motor's nameplate.

Note:

a. Single phase motors are typically dual voltage. In some cases, three phase motors are tri-voltage. Check the

nameplate and follow the proper wiring procedure for the voltage you are using. Improperly wiring the motor
could result in damage to the motor.

b. Three phase motors require a control box. Install overload protection to help prevent motor damage.

c. Depending on the wiring, three phase motors may start in reverse. Interchange any two power leads to

change the starting direction and pump rotation.

• Always follow correct operating procedures.

• Always disconnect the motor/pump assembly from all power sources before servicing the pump or motor.

• Periodically check all power connections, bolts, screws, and the motor's mounting.

• Failure to properly follow assembly and operating instructions could result in damage to the pump and motor.

• Failure to properly install the impeller and impeller nut could result in damage to the pump and could cause

serious personal injury.

WARNING

Initial Operation

Make certain the motor is not connected to a power source until the motor is properly assembled and mounted.
Serious personal injury or damage to the motor/pump assembly could occur if the motor is activated improperly.

Only certified electricians should make electrical connections.

1. Prime the pump by adding fluid to the volute case through the top plug.To properly prime the pump, venting

may be required.

2. Check the nameplate on the motor to determine the correct wiring procedure for your intended power

source and if the motor is single or three phase. Connect the motor to a power source by following the wiring
procedure on the motor's nameplate.