4.1
Make sure that the system is properly installed and primed as instructed in section 3.
4.2
STArTING- When the pump is up to operating speed, open the discharge valve to obtain desired
capacity or pressure.
4.3
Check to make sure all electric connections are correct.
4.4
Apply power to the motor.
Check motor rotation. rotation should be clockwise when viewed from the top.
Check that the noise, vibration, pressure, voltage and amps are at normal levels.
4.5
Please refer to the motor manufacturer specifications for starts per hour.
EVMU pumps are designed for continuous and normal off/on operation.
raPID CyCLING CaN CaUSE HIGH HEaT aND LOaDING THaT CaN CaUSE DaMaGE
TO THE PUMP Or MOTOr.
Section 4 – Operation
WarNING
!!
OPEraTING THE PUMP WITHOUT THE GUarDS IN PLaCE CaN CaUSE PHySICaL INjUry.
WarNING
!!
DO NOT aLLOW THE PUMP TO rUN WITH THE DISCHarGE VaLVE TIGHTLy CLOSED. IF THE
PUMP rUNS FOr aN ExTENDED PErIOD OF TIME WITHOUT LIQUID bEING DISCHarGED,
THE LIQUID IN THE PUMP CaSE CaN GET ExTrEMELy HOT CaUSING SEVErE DaMaGE TO
THE PUMP aND POSSIbLy CaUSE INjUry TO PEOPLE.
WarNING
!!