Technical specifications, 7 technical specifications, 1 technical specifications – DE DIETRICH INNOVENS MCA 15 - MCA 25 - MCA 25_28 MI User Manual

Page 40

Advertising
background image

7 Technical specifications

7.1

Technical specifications

Boiler type

MCA 15

MCA 25

MCA 25/28 MI

General
Flow rate setting

Adjustable

Modulating, Start/Stop, 0 - 10 V

Nominal output (Pn)

Heating System (80/60 °C)

minimum-maximum kW

3,0 - 14,5

5,0 - 24,1

5,0 - 24,1

Factory setting

kW

14,5

24,1

19,4

Nominal output (Pn)

DHW System

minimum-maximum kW

-

-

5,0 - 28,6

Factory setting

kW

-

-

28,6

Data on the gases and combustion gases
Gas consumption - Natural gas H (G20) minimum-maximum m

3

/h

0,33 - 1,59 0,55 - 2,65 0,55 - 2,96

Gas consumption - Propane G31

minimum-maximum m

3

/h

0,13 - 0,61 0,21 - 1,02 0,21 - 1,15

NOx-Emission per year (n =1)

mg/kWh 33

38

38

Characteristics of the heating circuit
Water content

l

1,7

1,7

1,7

Water operating pressure (PMS)

maximum

kPa (bar) 300 (3,0)

300 (3,0)

300 (3,0)

Water temperature

maximum

°C

110

110

110

Operating temperature

maximum

°C

90

90

90

Characteristics of the domestic hot water circuit
Specific hot water flow D (60 °C)

l/min

-

-

8,2

Specific hot water flow D (40 °C)

l/min

-

-

13,7

Flow rate threshold

minimum

l/min

-

-

1,2

Operating pressure (Pmw)

maximum

kPa (bar) -

-

800 (8,0)

Electrical characteristics
Power supply voltage

VAC

230

230

230

Power consumption - Full load

maximum

W

88

116

124

Factory setting

W

53

72

72

Electrical protection index

IPX4D

IPX4D

IPX4D

Other characteristics
Total weight (empty)

kg

43

43

44

Acoustic level at 1 metre at high speed

dBA

35

42

44

7. Technical specifications

MCA 15 - MCA 25 MCA 25/28 MI

39

23/08/2011 - 300024159-001-B

Advertising