4.4

Installation shutdown

CAUTION

Do not switch off the boiler. If the central heating system

is not used for a long period, we recommend activating the
HOLIDAYS

mode.

4.5

Frost protection

When the heating water temperature in the boiler falls by too much,

the integrated protection system in the boiler starts up. This protection

functions as follows:

4

If the water temperature is lower than 7°C, the heating pump starts

up.

4

If the water temperature is lower than 4°C, the boiler starts up.

4

If the water temperature is higher than 10°C, the boiler shuts down

and the heating pump continues to run for a short time.

4

If the water temperature in the storage tank is less than 7°C, it is

reheated to its set point.

CAUTION

4

The anitfreeze protection does not function if the

boiler is switched off.

4

The integrated protection system only protects the

boiler, not the installation. To protect the installation,

set the appliance to HOLIDAYS mode.

The HOLIDAYS mode protects:

4

The installation if the outside temperature is lower than 3°C

(factory setting).

4

The room temperature if a remote control is connected and the

room temperature is lower than 6 °C (factory setting).

4

The domestic hot water tank if the tank temperature is lower

than 4 °C (the water is reheated to 10 °C).