7 technical characteristics, Technical characteristics – DE DIETRICH WHE 2.24, WHE 2.24 FF-3S, WHE 2.28 FF User Manual

Page 12

Advertising
background image

12

WHE 2.24 / WHE 2.24 FF-3S / WHE 2.28 FF

22/07/2008 - 300017625-001-B

7 Technical characteristics

Conditions of use:
- Max. safety temperature: 95 °C
- Safety thermostat: 105 °C

WHE 2.24

WHE 2.24 FF-3S

WHE 2.28 FF

Nominal input power

kW

26.6

25.4

30.6

Nominal useful output

kW

24

23.6

28

Minimum useful output

kW

8.4

8.4

9.8

Maximum output

kW

24

23.6

28

Efficiency (80/60 °C)

%

90.1

92.9

91.5

Gas flow rate

Natural gas (Pmax)

m

3

/h

2.77

2.65

3.19

Natural gas (Pmin)

m

3

/h

0.97

0.96

1.12

Butane / Propane

Kg/h

2.08

1.99

2.39

Heating

Minimum output temperature

°C

35

35

35

Maximum output temperature

°C

80

80

80

Minimum operating pressure

bar

0.8

0.8

0.8

Maximum operating pressure

bar

3

3

3

Domestic hot water

Minimum output temperature

°C

35

35

35

Maximum output temperature

°C

60

60

60

Minimum operating pressure

bar

0.3

0.3

0.3

Maximum operating pressure

bar

10

10

10

Minimum flow

l/min

3

3

3

Specific flow at

∆t=30K

l/min

11.4

11.4

13.4

Combustion products circuit

Mass flue gas flow rate (min / max)

Kg/h

70/75

59/50

69/62

Flue gas temperature (min / max)

°C

84/124

98/135

102/146

Value CO

2

(min / max)

%

1.8/4.9

2.1/7.1

2.1/6.9

Maximum pressure at the flue gas nozzle

Pa

-

35

31

Gas connection

inch

R 3/4

R 3/4

R 3/4

Heating connection

inch

R 3/4

R 3/4

R 3/4

Domestic hot water connection

inch

R 1/2

R 1/2

R 1/2

Electrical connection

V/Hz

230/50

230/50

230/50

Electrical power

W

105

150

150

Expansion vessel capacity

l

8

8

8

Net weight (without water)

kg

34.7

40.8

41.3

Dimensions

mm

750 x 454 x 340

750 x 454 x 340

750 x 454 x 340

Insulation class

IP20

IPX4D

IPX4D