DE DIETRICH 220 SHL User Manual

Page 10

Advertising
background image

DHW tank 220SHL
Maximum operating pressure

bar 10

Water content

l

220

Top up volume

l

85

Solar volume

l

135

Weight
Shipping weight (Foam coated domestic hot water tank) kg 109

Performances related to the boiler type

Gas fired floor-standing condensing boiler

(1)

10/15 kW

15 kW

25 kW

35 kW

Power exchanged

kW

15

15

28

32

Flow per hour (∆T = 35°C)

(2)

l/h

370

370

690

790

Specific flow (∆T = 30°C)

(3)

l/min

20

20

24

26

Draw-off capacity

(3)

l/10 mm

200

200

240

260

Q

p

: Primary flow rate

m

3

/h

0.45

0.45

0.80

1.00

(1) Depending on the country in which the boiler is installed

(2) Domestic cold water inlet: 10 °C - Domestic hot water outlet: 45 °C - Primary circuit (heating water): 80 °C

(3) Domestic cold water inlet: 10 °C - Domestic hot water outlet: 40 °C - Primary circuit (heating water): 80 °C - Calorifier temperature: 60 °C

Performances related to the boiler type

Floor-standing condensing oil boiler

(1)

18 kW

24 kW

30 kW

Power exchanged

kW

18

24

30

Flow per hour (∆T = 35°C)

(2)

l/h

440

590

740

Specific flow (∆T = 30°C)

(3)

l/min

21

24

25

Draw-off capacity

(3)

l/10 mm

210

240

260

Q

p

: Primary flow rate

m

3

/h

0.75

0.75

0.85

(1) Depending on the country in which the boiler is installed

(2) Domestic cold water inlet: 10 °C - Domestic hot water outlet: 45 °C - Primary circuit (heating water): 80 °C

(3) Domestic cold water inlet: 10 °C - Domestic hot water outlet: 40 °C - Primary circuit (heating water): 80 °C - Calorifier temperature: 60 °C

3.3

Composition of the NF CESI solar systems packages (for France only)

Check the composition of the NF CESI solar system package against

the table below. The references and packages listed must be shown

on the invoice for the system sold by the installer.

A system is complete and functional according to the NF CESI mark

if all system references appear on the invoice. The system is

composed of the following elements:

4

A collector field with 1 or 2 solar collectors.

4

A boiler system (Modulens or OEnoviaGas Confort / OEnoviaFioul

Confort) + solar domestic hot water tank to which a solar station

is mounted in the factory, which includes a heating pump, an

expansion vessel and a Diemasol A / Oetrosol A control system.

4

The solar fluid that protects the installation from frost and

corrosion.

3. Description

220 SHL

9

18/10/2012 - 300028214-001-02

Advertising