5 cleaning and regular servicing, 1 cleaning the boiler (every 3 to 7 days), 2 maximum quantity of ashes – DE DIETRICH CBI-II _ CBB 15 E User Manual

Page 11: Cleaning and regular servicing

Advertising
background image

11

16/06/2009 - 300019729-001-C

CBI-II / CBB 15 E

5. Cleaning and regular servicing

5 Cleaning and regular servicing



Remove ashes from the boiler every 3 to 7 days depending
on the quality and quantity of wood used.



Clean the flue gas collector and the fan around 1 time per
month.



At the end of the heating season, have the boiler
thoroughly cleaned by a qualified professional.

5.1 Cleaning the boiler (Every 3 to 7 days)



Turn the boiler off before cleaning.
See chapter: Stopping the boiler

1. Turn the flue gas thermostat to 0 (Ignition) - except CBB 15 E.

2. Open the loading door.

3. Sweep the ashes through the smoke evacuation slit.

4. Open the ashtray door. Remove ashes and soot using the

ashtray and a scraper.

5. Clean the area around the ceramic combustion chamber

Do not remove the refractory components during cleaning.

5.2 Maximum quantity of ashes

2. Combustion chamber
3. Maximum quantity of ashes

4. Baffle

0

MAX

MIN

1

3 5

2

C002322-A

4

3

4

5

1

2

3

M000351

100

CBI-II-20, 30, 40
CBB 15 E

Advertising