Changing the settings, Setting the set point temperatures, 3 changing the settings – DE DIETRICH AWHP-2 MIT-IN-2 iSystem User Manual

Page 18

Advertising
background image

User level - Menu #MEASURES
Parameter

Description

Unit

DT INSTALLATION

Installation temperature delta

K

ELEC.ENERGY

(1)

Total electrical energy consumed

kWh

ELEC.ENERG.Y1

(1)

Total electrical energy consumed in the previous year

kWh

ELEC.ENERG.Y2

(1)

Total electrical energy consumed two years ago

kWh

THERM.ENERGY

(1)

Total thermal energy yield

kWh

THERM.ENERG.Y1

(1)

Total thermal energy yield in the previous year

kWh

THERM.ENERG.Y2

(1)

Total thermal energy yield two years ago

kWh

(1) The parameter is only displayed for the options, circuits or sensors actually connected.

4.3

Changing the settings

4.3.1.

Setting the set point temperatures

To set the various heating, DHW and swimming pool temperatures,

proceed as follows:
1. Press the C key.
2. To select the desired parameter, turn the rotary button.
3. To modify the parameter, press the rotary button.

To go back to the previous display, press the key j.

4. To modify the parameter, turn the rotary button.
5. To confirm, press the rotary button.

To cancel, press key h.

Menu C
Parameter

Adjustment range Description

Factory setting

DAY TEMP.A

5 to 30 °C

Desired room temperature in comfort periods on circuit A

20 °C

NIGHT TEMP.A

5 to 30 °C

Desired room temperature in reduced periods on circuit A

16 °C

ROOMTEM.COOL A

(1)

(2)

22 to 30 °C

Desired room temperature set point in cooling mode

25 °C

DAY TEMP.B

(2)

5 to 30 °C

Desired room temperature in comfort periods on circuit B

20 °C

NIGHT TEMP.B

(2)

5 to 30 °C

Desired room temperature in reduced periods on circuit B

16 °C

ROOMTEM.COOL B

(2)

(1)

22 to 30 °C

Desired room temperature set point in cooling mode

25 °C

DAY TEMP.C

(2)

5 to 30 °C

Desired room temperature in comfort periods on circuit C

20 °C

NIGHT TEMP.C

(2)

5 to 30 °C

Desired room temperature in reduced periods on circuit C

16 °C

ROOMTEM.COOL C

(2)

(1)

22 to 30 °C

Desired room temperature set point in cooling mode

25 °C

DHW TEMP.

(2)

10 to 65 °C

Desired domestic hot water temperature in the DHW circuit 55 °C

(1) The parameter is only displayed if the corresponding circuit can handle cooling.

(2) The parameter is only displayed for the options, circuits or sensors actually connected.

MODE

C002266-A

4. Operating the appliance

AWHP-2 MIT-IN-2 iSystem

17

31/03/2014 - 7616372-001-02