5 alarm wire diagram – eLine Technology ANPTZ-56-37R User Manual
Page 15

eLineTechnology.com
13
1) Protocol Rule
Protocol
SW1-1
SW1-2
SW1-3
Auto Match/PELCO-D
OFF
OFF
OFF
TA OFF
OFF
ON
PELCO-P ON OFF OFF
Save ……
……
……
2) Baud Rate Rules
Baud Rate
SW1-4
SW1-5
Auto Match/1200BPS
OFF
OFF
2400BPS ON
OFF
4800BPS OFF
ON
9600BPS ON
ON
3) 120Ω ohmic resistance Configuration
SW1 is the 120Ω ohmic resistance of RS485. Please configure it as the 《Appendix 2 RS485 BUS
Connection》.
4) Communicated Address Configuration
SW2 configure the Speed Dome address. The speed dome address is binary system, No.8 is MSB,
No.2 is the LSB. PELCO-D/TA please refer as Appendix 5 <Table of Address Code> .
2.5 Alarm Wire Diagram
Speed Dome support 4 channel alarm output and 2 channel input; Following is the diagram.
Port Name
Description
COM1
Alarm Output Channel , 1 Common Port
NO1
Alarm NO Output Channel 1
COM2
Alarm Output Channel 2 Common Port
NO2
Alarm NO Output Channel 2
GND
Alarm Output GND
IN 4
Alarm Input Channel 4
IN 3
Alarm Input Channel 3
IN 2
Alarm Input Channel 2
IN 1
Alarm Input Channel 1
GND
Alarm Input GND