Fill-Rite FRHP32V User Manual

Page 2

Advertising
background image

Safety Information
























Installation

 

WARNING! To ensure safe and proper operation of your equipment, it is critical to read and adhere to all of the following
safety warnings and precautions. Improper installation or use of this product can cause damage to the device and
serious bodily injury or death!

1) When using the FRHP32V and FRAP32V with Diesel Exhaust Fluid, maintaining the purity of the DEF / AUS32

(Aqueous Urea Solution 32.5%) is critical; as such, it is imperative once the system is assembled, it must remain
sealed to ensure the integrity of the fluid. Breaking the seal on the system can lead to fluid contamination.

2) After dispensing DEF be certain to drain all the fluid from the nozzle, making sure it is pointing downward when

stored. DEF remaining in the nozzle tip and exposed to air will crystallize and can plug the nozzle.

3) DO NOT lay the dispensing nozzle on the ground or any surface that may contaminate the nozzle tip as this can

compromise the purity of the DEF.

4) The base is designed to mount directly to the barrel bung; as such it has 2” NPS threads. Plumbing sealant

appropriate for the fluids and chemicals being dispensed is highly recommended; the 2” threaded bung mount does
not require sealant.

5) Storage tanks should be securely anchored to prevent shifting or tipping when full or empty.
6) If the pump will see periods of low or no use, flush it regularly when pumping DEF, corrosive materials, or fluids that

harden. If the pump is used for DEF, use only DEF or de-ionized water to flush the pump (FRHP32V and FRAP32V
applications).

7) DO NOT use the pump with fluids intended for human consumption.
8)

WARNING! This pump is not for use with fluids that have a flash point below 100°F (37.8°C, ie: gasoline, alcohol).

Refer to NFPA 325M (Fire Hazard Properties of Flammable Liquids, Gases, and Volatile Solids) for flash points of
common liquids. Static electricity buildup and discharge could result in arc and explosion.

9) On hand operated pumps, leave the handle in the down position when not in use to prevent accidental dispensing of

fluid.

FR20V and FRHP32V Hand Operated Pumps

Installation
1) Apply thread sealant tape or compound (appropriate for the fluid to be pumped) to the suction tube threads; screw tube into

the pump inlet.

2) Slide suction pipe into tank or barrel.
3) Screw pump into tank or barrel application until the spout faces the desired direction for dispensing.
4) Tighten the lock ring securely onto the tank or barrel.
5) If applicable, attach dispensing hose to spout outlet; clamp securely in place.

FRAP32V Air Operated Pump

Installation
1) Apply thread sealant tape or compound (appropriate for the fluid to be pumped) to the suction tube threads; screw tube into

the pump inlet.

2) Adjust length of suction tube to desired level.
3) Screw pump into tank or barrel application until the spout faces the desired direction for dispensing.
4) Tighten the lock ring securely onto the tank or barrel
5) Attach air supply line to air inlet on pump.

6) Pull up adjusting knob on top of the regulator.
7) Open air inlet valve to begin flow of fluid; discharge into a suitable container.
8) Adjust air pressure by rotating the knob on top of the regulator until a smooth flow is achieved.
9) Push regulator knob down to lock it into place.
10) Close air inlet valve to stop flow.
11) If applicable, attach dispensing hose to spout outlet; clamp securely in place.

WARNING!  DO NOT EXCEED 100 psi AIR PRESSURE ON AIR SUPPLY LINE!