Brooks Instrument Model 1307 O-ring Seal Flowmeter

1-4

Table 1-2. Pressure Ratings.

Meter

Maximum Working

Max.

Size

Pressure (psig)

Temp.

Gas

Service

7

350

8

300

9

175

250°F

10

100

(121°C)

12

75

13

100

1. Pressure ratings are based on static pressure applicable at

250°F.

2. Glass tubes are not usable for caustic service.
3. Fluid temperatures below 32°F will cause frosting of the glass

metering tube. Please consult factory for applications below
this temperature.

Figure 1-1. Float Types.

READ
HERE

Spherical -
Lowest meter capacity and
no viscous fluids with medium
capacity.

Type LJ -
Maximum flowmeter capacity
with limited viscosity
immunity.

READ
HERE

Type RV (rib guided) -
Highest immunity to viscous
fluids with medium meter
capacity. (Most stable)

Type GV (rod guided) -
Analogous in design to a
sharp edge orifice. Gives
most immunity to viscosity
variations of the fluid being
metered.

READ
HERE

Type RV

(Rib guided)

Type RS (rib guided) - High
flow capacity with some
immunity to viscous fluids.

Type GS (rod guided) -
Analogous in design to a flow
nozzle or venturi. Offers the
maximum flow capacity in any
given size flowmeter.

READ
HERE

Type RS

(Rib guided)

Type LJ

Spherical