Procedure:

→

Connect coil body to the core guide pipe.

→

Screw on coil with nut. Observe torque.

→

Check protective conductor.

note!

Device will be damaged if the wrong tools are used!
Always use a wrench to tighten nut. If other tools are used (e.g. pliers),

the device may be damaged.

Observe torque for fas-

tening nut (see table)

Torque:

Type

DN

Torque

0406

13 - 25

6 Nm

0407

13 - 40

50, 65

15 - 16 Nm
18 - 20 Nm

7.3. malfunctions
If malfunctions occur, check:

→

the device has been installed according to the instructions,

→

the electrical and fluid connections are correct,

→

the device is not damaged,

→

all screws have been tightened,

→

the voltage and pressure have been switched on,

→

the pipelines are clean.

Valve does not switch
Possible cause:
• Short circuit or coil interrupted,
• Core or core area dirty.

english

• Medium pressure outside the permitted pressure range.

Valve does not close
Possible cause:
• Internal space of the valve is dirty.
• Small control bore in the piston blocked.

8.

spare parts

CAutIon!

Risk of injury and/or damage by the use of incorrect parts!
Incorrect accessories and unsuitable spare parts may cause injuries
and damage the device and the surrounding area.
• Use only original accessories and original spare parts from Bürkert.

8.1. Ordering spare parts
Order the spare part sets specifying the positions
(Pos. 1: Coil set, Pos. 2 and Pos. 3: Wearing part set) and the identi-
fication number of the device.

english

8.1.1. torque

Type

DN

Cover

screws

Flange screws

Plug with pipe

0406

13

3 - 4 Nm

2 Nm

-

20

6 - 7 Nm

2 Nm

-

25

9 - 10 Nm

2 Nm

-

0407

13

3 -4 Nm

-

80 - 85 Nm

20

6 - 7 Nm

-

80 - 85 Nm

25 - 40

9 - 10 Nm

-

80 - 85 Nm

50, 65

15 - 17 Nm

-

110 - 115 Nm

8.2. Overview of spare parts

1

2

3

1

2

Type 0406

Type 0407

english