1 assembly 7.2 commissioning – Burkert Type 0641 User Manual

Page 13

Advertising
background image

13

Installation and Commissioning

DANGER!

High voltage!
Acute risk of injury from hazardous structure-borne voltage!
Risk of damage to the device due to short circuit!

▶ Work on the electrical system may only be carried out by quali-

fied electricians.

▶ Before starting work, switch off the power supply and secure to

prevent it being switched on again!

▶ Live terminals in the terminal box can cause electric shock, short

circuit or explosion. Switch off the power supply before open-

ing the terminal box.

▶ The connecting cables to the electromagnets must be secure,

and be laid so that they are adequately protected from mechani-

cal damage.

▶ Observe the applicable accident prevention and safety regula-

tions for electrical devices!

WARNING!

Pressurised system!
Interventions in the pneumatic system represent an acute risk of
injury.

▶ Work on the pneumatic system may only be carried out by quali-

fied and instructed personnel using appropriate tools.

▶ First switch off pressure before disconnecting lines and valves.

▶ Observe the flow direction during installation!

▶ Observe the applicable accident prevention and safety regula-

tions for pneumatic systems!

7.1 Assembly

NOTES!

Installation in any position.
Preferably with solenoid system mounted at the top.
The devices are suitable for individual and block assembly..

→

Clean the pipe runs.

→

Connect a dirt-trap (strainer) upstream. Note the direction of flow!

→

Seal PTFE.

→

Screwing on the pipe run. Note the direction of flow!

→

Installation / Dismounting.

NOTES!

Always connect the earth conductor!
Note for units with connecting cable: The connecting cable and the
coil are moduled together. They must not be dismantled!

→

Make electrical connections.

7.2 Commissioning

Before commissioning, ensure that
• the device has been correctly installed,
• the connections have been correctly made,
• the device is not damaged,
• all bolts are securely tightened.

english

PTB 02 ATEX 2094 X

Advertising