4 installation and commissioning, English – Burkert Type 6022 User Manual

Page 18

Advertising
background image

18 - 03 ATEX5014 X

english

4 INSTALLATION AND COMMISSIONING

DANGER!

Danger of explosion!
•

The device is a sealed system.

The unit must not be dismantled!

The following safety regulations must be observed:
•

The surface of the device may develop an electrostatic charge.
In areas with an explosion hazard, the surface of the units may only be
cleaned with a damp cloth!

•

Only permanently laid cables and wiring may be inserted.

•

The operator must provide suitable stress relief.

•

Wires with an outside diameter of 6 to 13 mm may be used. Observe
the maximum thermal loading of the cables or wires to be inserted.

•

The inserted break-off seal must be matched to the diameter of the
cable or wire.

•

The rated cross-section of the cable or wire strands must be at least
0.75 mm² and may not exceed 2.5 mm².

•

The screws for fixing the cover of the terminal box must be tightened
with a torque of 100 Ncm (±5%).

DANGER!

High voltage!
Acute risk of injury from hazardous structure-borne voltage!
Risk of damage to the device due to short circuit!
•

Work on the electrical system may only be carried out by qualified
electricians.

•

Before starting work, switch off the power supply and secure to pre-
vent it being switched on again!

•

Live terminals in the terminal box can cause electric shock, short circuit
or explosion. Switch off the power supply before opening the terminal
box.

•

The connecting cables to the electromagnets must be secure, and be
laid so that they are adequately protected from mechanical damage.

•

Observe the applicable accident prevention and safety regulations for
electrical devices!