Start-up

Control functions A and B:

→

Connect the control medium to the pilot air port 1 of the actuator
(see “Fig. 6”).

Silencer
For the versions with a plug-in connection the silencer for reducing
the exhaust air noise is supplied loose.

→

Plug the silencer into the free air discharge connection 2 (see
“Fig. 6”).

If used in an aggressive environment, we recommend con-
veying all free pneumatic connections into a neutral atmo-
sphere with the aid of a pneumatic hose.

Control function I:

→

Connect the control medium to the pilot air port 1 and 2 of the
actuator (see “Fig. 6”)
Pressure on connection 1 opens the valve.
Pressure on connection 2 closes the valve.

1

2

Pilot air port

CFA, CFB, CFI

Air discharge connection

CFA, CFB

Pilot air port CFI

Fig. 6:

Pneumatic connection

Control air hose:
6/4 mm or 1/4“ control air hoses can be used.
Optionally a pilot air port is possible via a G 1/8 thread.

8. START-UP

8.1. Safety instructions

WARNING!

Risk of injury from improper operation!
Improper operation may result in injuries as well as damage to the
device and the area around it.
• Before start-up, ensure that the operating personnel are familiar

with and completely understand the contents of the operating

instructions.

• Observe the safety instructions and intended use.
• Only adequately trained personnel may operate the equipment/

the device.

8.2. Pilot pressure

WARNING!

For control function I – Danger if pilot pressure fails!
For control function I control and resetting occur pneumatically. If
the pressure fails, no defined position is reached.
• To ensure a controlled restart, first pressurize the device with

pilot pressure, then switch on the medium..

→

Set the pilot pressure according to the type label specifications,
chapter “6. Technical data” and flow direction (chapter “8.3.
Flow direction”).