Technical data
7.4.
Operating conditions
Observe permitted ranges on the type label of the device!
7.4.1. Temperature ranges
Actuator
size
Actuator
material
Medium
(for PTFE seal)
Environment
2)
ø 50 mm
PPS
-10 – +185 °C
0 – +60 °C
3)
0 – +100 °C
4)
ø 70 mm
ø 90 mm
ø 130 mm
Tab. 1: Temperature ranges
2)
If a pilot valve is used, the max. ambient temperature is
+55 °C
The angle seat valve is suitable for steam sterilization.
3)
Pilot air ports with push-in connector
4)
Pilot air ports with threaded bushing
7.4.2. Pressure ranges
Actuator size
Maximum pilot pressure
5)
ø 50 mm
10 bar
ø 70 mm
ø 90 mm
ø 130 mm
7 bar
Tab. 2: Pressure ranges
5)
For the device version ø 70 / Orifice 50 / MC 13 the
max. permitted pilot pressure is limited to 7 bar.
english
Type 2100