Burkert Type 2101 User Manual

Page 30

Advertising
background image

30

Maintenance,Cleaning

remove the actuator from the valve body:

→

Clamp the valve body in a holding device
(applies only to valves which have not yet been installed).

noTe!

damage to the seat seal or the seat contour!

▶ When removing the actuator, ensure that the valve is in open

position.

→

Control function A pressurize the pilot air port 1 with com-
pressed air (5 bar): valve opens.

→

Using a suitable open-end wrench, place the wrench flat on the
tube.

→

Unscrew the actuator from the valve body.

Actuator

Nipple

Valve body

Air discharge connection

CFA, CFB

Pilot air port

CFI

Pilot air port

CFA, CFB, CFI

Flats for open-end

wrench

Release bore

2

1

Fig. 24: Designation parts

removing the swivel plate

→

Knock out the pin with a suitable pin punch.
pin punch ø 3 mm, for spindle diameter 10 mm on the swivel
plate.
pin punch ø 5 mm, for spindle diameter 14 mm on the swivel
plate.

→

Remove swivel plate.

Spindle

Pin

Swivel plate

Graphite seal

Fig. 25: Valve set