Technical data

Type 2301

Actuator
Nipple

Valve body

Flats for open-end

wrench

Pilot air port

CFA, CFB, CFI

Exhaust air port

CFA, CFB

Pilot air port CFI

2

1

Install collet:

Fig. 3:

Installation

other device versions

→

Do not remove actuator unless this is a customer-specific
requirement.

→

Procedure see “Devices with welded body”.

8.3. installation

Warning!

risk of injury from improper installation!
Assembly with unsuitable tools or non-observance of the tight-
ening torque is dangerous as the device may be damaged.
• For installation use an open-end wrench, never a pipe wrench.
• Observe the tightening torque (see “Tab. 5”).

dirt trap for devices with authorisation in accordance with din
en 161
In accordance with DIN EN 161 “Automatic shut-off valves for gas

burners and gas appliances” a dirt trap must be connected upstream

of the valve and prevent the insertion of a 1 mm plug gauge.

8.3.1. installation of the valve body

Welded bodies

→

Weld valve body in pipeline system.

other body versions

→

Connect body to pipeline.

8.3.2. install actuator (welded body)

Graphite seal

Fig. 4:

Graphite seal

→

Check the graphite seal and if required, replace it.

Warning!

danger if incorrect lubricants used!
Unsuitable lubricant may contaminate the medium. In oxygen appli-
cations there is a risk of an explosion!
• In specific applications, e.g. oxygen or analysis applications, use

appropriately authorized lubricants only.