1.

OPERATING INSTRUCTIONS

The operating instructions contain important information.
• Read the instructions carefully and follow the safety instructions

in particular, and also observe the operating conditions.

• Keep the instructions in a location where they are available to

every user.

• The liability and warranty for the proportional valve are void if the

operating instructions are not followed.

2.

INTENDED USE

The direct-acting proportional valve can be used as an actuating

element for the process control.
• Do not use in potentially explosive areas.
• Do not use outside.
• Operate only when in perfect condition and pay attention to correct

storage, transportation, installation and operation.

• Do not make any internal or external changes.

3.

BASIC SAFETY INSTRUCTIONS

These safety instructions do not make allowance for any contin-

gencies and events which may arise during installation, operation

and maintenance.

WARNING!

Danger – high pressure!
• Before loosening lines or valves, turn off the pressure and vent

the lines.

Risk of burns/risk of fire if used continuously through hot

device surface!
• Keep the proportional valve away from highly flammable sub-

stances and media and do not touch with bare hands.

• Do not obstruct the heat release required for operation.
To prevent injury, ensure the following:
• Secure equipment/device from unintentional actuation.
• Only trained technicians may perform installation and mainte-

nance work.

• After an interruption in the power supply, ensure that the pro-

cess is restarted in a controlled manner.

• Observe the general regulations of technology.

Electrostatic sensitive components/modules!
Observe the requirements in accordance with EN 61340-5-1 and

5-2 to minimize/avoid the possibility of damage caused by a sudden

electrostatic discharge!

4.

TECHNICAL DATA

4.1. Operating conditions

CAUTION!

Malfunction in unauthorized temperature range.
• Avoid exceeding or dropping below the temperature range.

Ambient temperature:

0 ... +55 °C

Medium temperature:

-10 ... +90 °C

Media: neutral gases, technical vacuum
Protection class: IP65 in accordance with DIN EN 60529

4.2. Mechanical and pneumatic data

Materials, pressure range, line connectors: see rating plate

4.3. Electrical Data

Operating voltage, power input: see rating plate.

Nominal operating mode: Long-term operation ED 100 % in

accordance with DIN EN 60034-1

Electrical connection: (depending on type and design) wires, plug

tabs in accordance with DIN EN 175301-803 shape A, shape B

5.

INSTALLATION

WARNING!

Risk of injury from high pressure in the equipment.
• Before loosening lines or valves, turn off the pressure and vent

the lines.

Installation position: any position, preferably with actuator above.

→

Clean pipelines and flange connections.

→

Install dirt filter in the direction of flow in front of the valve

(mesh size 0.02 – 0.4 mm; according to orifice).

WARNING!

Danger from medium!
• Make sure that the supplied seal fits properly.

→

Insert seal into valve.

NOTE!
• The proportional valve must not be removed and the central

adjusting screw must not be adjusted.

Screwing in pipeline:

NOTE!
• Use suitable tool (open-end wrench)

and do not use coil as a lever arm.

→

Hold the proportional valve on the fluid

housing using an open-end wrench.

→

Screw in pipeline.

→

Check installation for leaks.

Attaching the mounting plate:

Fastening screws (2)

Mounting plate

mm*

* Coil size

Tightening torque

according to coil size:
20 mm = max. 1.0 Nm

32 mm = max. 1.2 Nm

49 mm = max. 1.5 Nm

Connecting device socket:

Seal

max.

0.9 Nm

NOTE!
• Note the voltage and current

type as specified on the rating

plate. Ensure that the seal is fitted

correctly.

→

Insert seal.

→

Attach device socket and secure

with screw.

Tightening torque max. 0.9 Nm.

→

Connect protective conductor.

6.

MAINTENANCE

Under normal operating conditions, the valve is maintenance-free.

7.

MALFUNCTIONS

If malfunctions occur, check
• the line connectors,
• whether the operating pressure is within the permitted range,
• the power supply and valve control.

8.

TRANSPORTATION, STORAGE, DISPOSAL

• Transport and store the proportional valve in shock-resistant

packaging to protect against moisture and dirt.

• Permitted storage temperature: -20 … +70 °C.
• Dispose of the device and packaging according to the appli-

cable disposal and environmental protection regulations.

Type 2861 ... 2875