9. malfuncTiOns

If malfunctions occur, check whether:

→

the device has been installed according to the instruc-
tions (correct direction of installation),

→

the connection has been made properly,

→

the device is not damaged,

→

all screws have been tightened,

→

the voltage and pressure have been switched on,

→

the pipelines are clean.

If the magnet is not attracting
Possible causes:
• Short circuit or coil interrupted,
• Core or core area dirty.

After occurrence of an external fire
• After an external fire, check the equipment and safety

shut-off device.

• If there is visible damage, replace safety shut-off device.

english

21

10. spare parTs

Caution!

Risk of injury and/or damage by the use of incorrect
parts!
Incorrect accessories and unsuitable spare parts may cause
injuries and damage the device and the surrounding area.
• Use original accessories and original spare parts from

Bürkert only.

Fittings set

Coil set

Nut

Nut and coil set can
be ordered com-
pletely by quoting
the identification
number of the
device (see type
label).

Fittings set on
request.

Fig. 6:

Spare parts

english

21

22

11. packaging, TranspOrT,

sTOrage, dispOsal

note!

Transport damages!
Inadequately protected equipment may be damaged
during transport.
• During transportation protect the device against wet

and dirt in shock-resistant packaging.

• Avoid exceeding or dropping below the allowable

storage temperature.

Incorrect storage may damage the device.
• Store the device in a dry and dust-free location!
• Storage temperature. -30 … +80 °C.
Damage to the environment caused by device compo-
nents contaminated with media.
• Dispose of the device and packaging in an environ-

mentally friendly manner.

• Observe applicable regulations on disposal and the

environment.

• Observe national waste disposal regulations.