9
Technical data
6.4.1. Rating plate
Designation Ex-protection
Identnumber, production date
Serial number
Technical data (see chapter 6.5 and 6.6)
Drawing-No. of coil
Designation IECEx-protection
MADE
IN
GERMANY
II 2G
Ex ia IIC T6 Gb
II 2D
Ex ia IIIC T80°C Db
AC10-Z3-6-PD94 IP54
P,U,I,Tamb s.manual
S/N
999999 W24LA
Fig. 2: Description of the rating plate
6.5.
Use in potentially explosive
areas of gas
The device may be used either in the hazardous area of gas
or dust but not in a hybrid mixture.
6.5.1. Electrical data
Electrical data for ignition protection type Ex “ia” and gas group II C:
Coil
size
L x W x H
[mm]
Mass
[g]
Encoding
Structure
Temp.
class
5
45 x 32 x 41
160
PD89
Diodes in the
coil
T6
PE28
T5
78 x 32 x 41
220
PD93
Diodes in the
device socket
T6
PE29
T5
6
50 x 40 x 41
210
PD94
Diodes in the
coil
T6
PE30
T5
83 x 40 x 41
270
PD95
Diodes in the
device socket
T6
PE31
T5
english
PTB 01 ATEX 2101