auTOrizEd usE

3.

Non-authorized use of the solenoid valve Type 6211
EV may be a hazard to people, nearby equipment
and the environment.

The device is designed to control, shut off and meter

•

neutral media up to a viscosity of 21 mm

2

/s.

Provided the cable plug is connected and installed

•

correctly, e.g. Bürkert Type 2507, the device satisfies

protection class IP65 in accordance with

DIN EN 60529 / IEC 60529.
During use observe the authorized data, the opera-

•

ting conditions and conditions of use specified in the

contract documents, on the rating plate and in the

operating instructions, as described in the chapter

entitled “

6.Technical Data”.

Correct transportation, correct storage and installation

•

and careful use and maintenance are essential for

reliable and faultless operation.
Use the device only as intended.

•

english

5

predictable misuse

3.1.

The device may only be used in the explosion-protected

•

area if an appropriate additional identification is attached
to the rating plate.
Do not put any loads on the housing (e.g. by placing objects

•

on it or standing on it).
Do not make any external modifications to the device hou-

•

sings. Do not paint the housing parts or screws.
The solenoid coil must not be thermally insulated, as it

•

heats up during operation. Ensure that the solenoid coil is
adequately ventilated.

restrictions

3.2.

If exporting the system/device, observe any existing
restrictions.

english

6

basic safETy

4.

insTrucTiOns

These safety instructions do not make allowance for any:

contingencies and events which may arise during the

•

installation, operation and maintenance of the devices.
local safety regulations – the operator is responsible for

•

observing these regulations, also with reference to the
installation personnel.

Danger – high pressure!

Before loosening the pipes and valves, turn off the

•

pressure and vent the pipes.

Risk of electric shock!

Before reaching into the device or the equipment,

•

switch off the power supply and secure to prevent

reactivation!
Observe applicable accident prevention and safety

•

regulations for electrical equipment!

Risk of burns/risk of fire if used for a prolonged
switch-on time through hot device surface!

Keep the device away from highly flammable substan-

•

ces and media and do not touch with bare hands.
Do not thermally insulate the unit and provide adequate

•

ventilation.

english

7

Risk of injury due to malfunction of valves with
alternating current (AC).
Sticking core causes coil to overheat, resulting in a
malfunction.

Monitor process to ensure function is in perfect working

•

order!

Risk of short-circuit/escape of media through leaking
screw joints.

Ensure seals are seated correctly!

•

Carefully screw valve and connection lines together!

•

General hazardous situations.
To prevent injury, ensure that:

the system cannot be activated unintentionally.

•

Installation and repair work may be carried out by

•

authorized technicians only and with the appropriate

tools.
After an interruption in the power supply or fluid sup-

•

ply, ensure that the process is restarted in a defined or

controlled manner.