7.4. Electrical connection of the

device socket

Warning!

Risk of injury due to electrical shock!
• Before reaching into the system, switch off the electrical

power supply and secure to prevent reactivation!

• Observe applicable accident prevention and safety

regulations for electrical equipment!

If the protective conductor contact between the coil and
housing is missing, there is danger of electrical shock!
• Always connect protective conductor.
• Check electrical continuity between coil and housing.

Authorized device socket e.g. Type
2508 in accordance with DIN ISO
175301-803 Form A

Seal

max. 1 Nm

Fig. 2:

Electrical connection of the device socket

english

17

Note the voltage and current type as specified on
the type label.

→

Tighten device socket (for permitted types see data
sheet), observing max. torque of 1 Nm.

→

Check that seal is fitted correctly.

→

Connect protective conductor and check electrical con-
tinuity between coil and housing.

english

18

8. mainTEnancE,

TrOublEshOOTing

8.1. safety instructions

Danger!

Risk of injury from high pressure in the equipment!
• Before loosening the lines and valves, turn off the pres-

sure and vent the lines.

Risk of injury due to electrical shock!
• Before reaching into the system , switch off the power

supply and secure to prevent reactivation!

• Observe applicable accident prevention and safety

regulations for electrical equipment!

Warning!

Risk of injury from improper maintenance!
• Maintenance may only be carried out by authorized

technicians with the appropriate tools!

Risk of injury from unintentional activation of the
system and an uncontrolled restart!
• Secure system from unintentional activation.
• Following maintenance, ensure a controlled restart.

english

19

8.2. installation of coil

Warning!

Escaping medium!
When a sticking nut is loosened, medium may escape.
• Do not tighten sticking nut any further.
Electric shock!
If the protective conductor contact between the coil and
housing is missing, there is danger of electrical shock!
• Check protective conductor contact after installing the

coil.

Overheating, risk of fire!
Connection of the coil without pre-assembled valve will
result in overheating and destroy the coil.
• Connect the coil with pre-assembled valve only.
Danger due to electrical shock if coil incorrectly installed!
• During installation ensure that the coil is seated firmly

on the step of the core guide tube so that the protective

conductor connection of the coil has a connection to

the valve housing.

Procedure:

→

Connect coil housing to the core guide pipe.

→

Screw on coil with nut. Observe torque.

→

Check protective conductor.

english