Burkert Type 8635 User Manual

Page 8

Advertising
background image

8

Particular safety instructions

PTB 04 ATEX 2027

in ignition protection class intrinsic safety ex ia iic only for connection to a certified intrinsically safe circuit.
Maximum values:

signal

terminal

ui

ii

Pi

ci

li

Current input

11, 12

30 V

100 mA

1 W

negligibly small

negligibly small

Process control input

13, 14

30 V

100 mA

1 W

14.3 nF

negligibly small

Interface RS 232

1)

X4 1 ... 3

8.8 V

100 mA

880 mW

negligibly small

negligibly small

Actual value output

31, 32

30 V

100 mA

1 W

negligibly small

negligibly small

Initiators

41, 42 and 51, 52

15.5 V

52 mA

150 mW

200 nF

0.2 mH

Binary outputs

83, 84, 85, 86

30 V

100 mA

1 W

negligibly small

negligibly small

1)

or for connection to a programming device outside the potentially explosive area: Um = 250 V

in ignition protection class intrinsic safety ex ia iic only for connection to a mechanical switch.
Maximum values:

signal

terminal

uo

io

co

lo

Binary input

81, 82

8.8 V

0.2 mA

5.5 µF

1000 mH

The connections for piezo valves, position measuring system, HART, display and pressure sensor board are intrinsically safe circuits.

english