20

Pneumaticinstallation

Procedure

→

Loosen the pneumatic connection between the Pneumatic
Control Unit and the actuator.

→

Loosen the fastening screws (hexagon socket wrench size 2.5).

→

Rotate the Pneumatic Control Unit into the required position.

noTe!

too high torque when screwing in the fastening screw does
not ensure degree of protection ip65 / ip67.

▶ The fastening screw may be tightened to a maximum torque of

0.5 Nm only.

→

Tighten the fastening screws hand-tight only (maximum torque:
0.5 Nm).

→

Re-attach the pneumatic connections between the Pneumatic
Control Unit and the actuator. If required, use longer hoses.

8

pneumaTic insTallaTiOn

Danger!

risk of injury from high pressure in the equipment/device.

▶ Before working on equipment or device, switch off the pressure

and deaerate/drain lines.

procedure:

→

Connect the control medium to the pilot air port (1)
(3 to 7 bar, oil, water and dust-free instrument air).

→

Attach the exhaust airline or a silencer to the exhaust air con-
nection (3).

Important information for the problem-free functioning of the
device:

▶ The installation must not cause back pressure to build up.

▶ Select a hose for the connection with an adequate cross-section.

▶ The exhaust air line must be designed in such a way that no water

or other liquid can get into the device through the exhaust air

connection.