57

Installation

→

Place new function module vertically on the distributor module (backplane bus) and press down until it clicks
into position.

→

Connect valve, with the cleanly inserted flange seals / O-rings, to the valve slot and tighten the screws
according to the following assembly diagram (see “Figure 30: Tightening the screws”).



20 Ncm

20 Ncm 30 Ncm

30 Ncm

Figure 30:

Tightening the screws

8.5.

fluid installation

DANgEr!

risk of injury from high pressure in the equipment!

• Before dismounting pneumatic lines and valves, turn off the pressure and vent the lines.

• Design the connections with the largest possible volume.

• Close the open connections not required with lock screws.

• The connections for the pilot control exhaust air (x) must not be sealed.

• Check that connections 1 and 3 or 5 have been configured correctly; these must not be mixed up.