GeneralAire TERsus 2000 User Manual

Page 5

Advertising
background image

4

cHangIng tHe uV LampS

Unplug the power cord from the GeneralAire TERSus air purification system. Unscrew the two locking knobs

1.

and remove the door. (Fig. 3)
Remove Photocatalytic module. (Fig. 4)

2.

Unplug UV lights, loosen retaining knobs, and remove UV lights. (Fig. 5, 6)

3.

Replace UV Lights, re-tension retaining knobs, and replace plug-ins.

4.

Replace Photocatalytic module and filter, secure door and re-insert power cord, check sight ports to ensure lamp

5.

illumination.

Note! Ensure filter and photocatalytic module are installed in proper air flow sequence.

fIg. 1

fIg. 2

Locking Knobs

fIg. 3

fIg. 4

fIg. 5

Unplug

UV Light

Loosen Retaining

Knobs. NOTE:

Tighten only finger

tight when installing

new lamps

reSettIng SerVIce LIgHtS

On the right side of the service panel, there are arrows pointing to two small holes marked reset. One marked filter

and one marked lamp. Using a small paper clip, bend out one leg straight and insert the end of the paper clip into

only the hole corresponding to the replaced component and push lightly until the service light returns to the green

position. The computer is now reset.

Press Here to Reset

Advertising
This manual is related to the following products: