Note: There may be some arcing or snapping sounds
from the collecting cells. This is normal when the unit is
new. In about 2 weeks, as the sharp edges of the cells
become smoother, the arcing will disappear.

OPERATION

The Air Cleaner will run as long as there is adequate

airflow through the ducts. The Air Cleaner will not run if
the system fan is off. For proper operation, follow these
simple steps:
1. Run heating/cooling system fan continuously, and on

low speed if available.

2. Remove furniture or carpets which block return air

grilles throughout your house, so that air moves
freely to the furnace/ air conditioner.

3. Check for proper operation of the system fan.

WHITE DUST

After installation of the Air Cleaner, you may notice

some white dust on tabletops and shelves. Most large
particles such as lint, are too heavy to remain airborne
and tend to settle quickly, never reaching the air cleaner.

This white visible dust is normally referred to as

“clean dust.” As the Air Cleaner is removing the dark and
staining particles from the air, the lint will also be cleaner.

Lint dust is most noticeable on dark furnishings; in

homes containing new carpeting; and where there is a lot
of household traffic from occupants and pets. To reduce
lint dust, use continuous fan operation and keep return
vents unrestricted to create an efficient airflow.
Note: The Air Cleaner does NOT produce more lint or
dust.

MAINTENANCE

It is important to follow a scheduled maintenance for
maximum performance of the Air Cleaner.

Cell And Prefilter Cleaning

The collecting cells and prefilters must be cleaned on a
regular basis for the Air Cleaner to function at its peak of
efficiency. The frequency of cleaning will vary from one
house to another. On average, the cells should be
cleaned every 3 months.
1. Remove access door, collecting cells and prefilters.
2. Place cells in a laundry tub. Rinse with hot water and

spray completely with DAX Detergent (or a non-
chlorine,

non-corrosive,

non-abrasive

liquid

household detergent. Allow detergent to run down
both sides of plates and ionizing wires. Let stand for
5 minutes or fill up laundry tub with water and DAX
Detergent, and dunk cells up and down until water is
dirty.

3. Rinse cells well with hot water (maximum 120°F/49°

C).

4. To remove contaminate from the ionizing wires use

an old toothbrush. Slide the brush bristles over the
wire and gently drag the brush up and down the wire
once. Be very careful when cleaning the wires as
they become very brittle with age.

5. If dirt remains on the cell plates, let the cells soak in a

solution of DAX Detergent and water for 30 minutes.

6. Tilt cells on 45° angle on their short side, with arrows

pointing

sideways.

Allow

to

dry

completely,

approximately 8-10 hours. A hair dryer may be used
to speed up drying time.

7. To wash prefilters, spray with DAX Detergent, rinse

and let dry. Do not wash in the same water as
collecting cells.

8. Do not place the cells in the air cleaner if they are

wet.

9. Place cells and prefilters back into cabinet. Close

door and turn power switch ON. If the performance
light does not come on or arcing occurs, turn Air
Cleaner OFF and allow air from system fan to dry
cells completely.

Activated Carbon Filter Replacement

Carbon filters help remove odors from the air. If the

Air Cleaner has been equipped with optional carbon
filters, they should be replaced every 3 - 6 months. Filters
are NOT washable. Replacements are available through

CAUTION

Make sure to turn Air Cleaner and system fan OFF
before performing any maintenance or removing any
components.

CAUTION

Damage to cells may occur if improperly handled or
washed. Do not wash cells in a dishwasher. Never use
any object to clean between the cell plates, as this may
cause damage to plates or ionizing wires. Never place
cell in oven to dry. The edges of the cell may be sharp -
handle with care.

6

Replacement Carbon Filters:

GA50A14

Set of 3 Part #EAC14-12

GA50A20, GA50A22

Set of 3 Part #EAC20-12

Fig. 6

— DAX Detergent and Carbon Filters are

DAX

32 oz Spray Bottle

Part #9900