8. With an ohmmeter, check continuity between the top,

center disc contact and one of the ionizing wires. The
reading should be close to 0 ohms. If not, bend the
contact to touch the ionizing bar.

9. Replace grilles, prefilters and cells. Turn ON the Air

Cleaner.


Replacing A Tungsten Ionizing Wire

Replacement wires are cut to the correct length and

have eyelets at each end for easy replacement.
1. Turn OFF power to Air Cleaner.
2. Remove cell from Air Cleaner.
3. Remove all parts of broken wire, as well as spring and

S-hook. If necessary, cell may be used temporarily
with one wire missing until a replacement is received.

4. Using needle-nose pliers, place spring hook in the

hole of the ionizing bar near cell top.

5. Place eyelet of wire over the S-hook and place S-hook

into hole on ionizing bar on other side of cell. Keep
wire tight to ensure S-hook remains in hole.

6. Using the needle-nose pliers, grab the end of the

spring and stretch towards loop in wire. Place eyelet in
wire over spring hook and release spring. See Fig 6.

7. Install cell in Air Cleaner.
8. Return power to Air Cleaner.
9. Test cell for proper operation.

Fig. 7

— Dimensions

Ionizing Bar

Spring

Wire

Fig. 6

— Replacing An Ionizing Wire

MODEL

GA52F32

HOUSE SIZE

n/a

AIR FLOW

up to 2000 cfm

DUCT SIZE

22 x 29.1 in

CABINET DIMENSIONS

31.4 x 24.4 x 7 inches

WEIGHT

38 lbs

POWER

120 v 60 hz

Table 2

— Specifications