GeneralAire GFX3 User Manual

Installation and operating instructions, Gfx3 locations

Advertising
background image

Thank you for

choosing the GeneralAire

GFX3 Humidistat!

About the GFX3 Digital Humidistat

In Automatic Mode the GFX3 will adjust the humidity in your home based on the outdoor tempera-

ture, lowering the humidity in cold weather to reduce condensation. The GFX3 can operate in

Manual Mode to control humidity to a specific relative Humidity. In most homes, Automatic

operation is preferred to reduce condensation on windows and within the structure. Manual mode

is necessary where the outdoor temperature sensor cannot be installed. Manual mode may be

desirable where valuable artwork, instruments or woodwork demand constant humidity. The LCD

Display is backlit and easy to read. Operation and Installation are simple. The GFX3 can be mounted

on an interior wall or on the return duct of the HVAC System.

Precautions

This Humidistat must be installed by a Qualified Technician. Always turn off power to the HVAC system prior to Installing or Servicing the Humidifier or Humidistat. Improper

operation can result in over or under humidification. Over humidification can result in condensation, structural damage or mold. Condensation within a building’s structure can

cause a loss of structural strength. Condensation can also enable mold and mildew growth resulting in personal injury and damage to building structure and contents. Older

and poorly insulated structures cannot withstand the same humidity levels as newer well insulated buildings. Read these instructions carefully. This humidistat requires a 24

volt, AC power supply. Improper voltage can cause malfunction or damage to the control. The technical specifications for this product and the contents of the user manual are

subject to change without notice.

Duct

Installation

Wall

Installation

Outdoor Sensor Location

YES !

North Wall

East Wall

Over Snow Line

Inlet of Air Intake

Less than 200’ from

humidistat.

NO!

South Wall

West Wall

Below Snow

Deep in Intake

More than 200’

from humidistat.

YES!

YES!

YES!

YES!

GFX3 Locations

1” Hole.

1” Hole.

Duct base: no vents.

If wires are run inside duct,

cut rectangular opening.

Secure the base with the

two sheet metal screws.

Wall base has vents.

If wires are run inside wall,

cut rectangular opening.

Secure the base with the

two plastic anchors and

screws.

INSTALLATION AND

OPERATING INSTRUCTIONS

Specifications

Voltage

Switching Load

Outdoor Sensor

Auto Mode

Control Range

Outdoor Temp.

18-30 VAC, 60Hz.

1 amp max. 30 volt

max. 200 ft. 61m.

10%-60% RH.

-10°F, -23°C min.

Manual Mode

Control Range

Accuracy -RH (77°F, 25°C)

Accuracy Drift Per Year

Accuracy Indoor Temp.

Accuracy Outdoor Temp

10%-75% RH

10%-90% ±3%RH

±0.5%RH

±2°F, ±1°C

±2°F, ±1°C

Resolution, Temp or RH

Relay Close

Relay Open

1° or 1%.

Setting - 1%RH

Setting +1%RH