14. Prepare the compressor for mounting by HAND-TIGHTENING the air filter
into the port on the compressor. If necessary, adapters are provided with the
compressor to connect nylon hose from the tank to the compressor hose. Do
not remove the braided hose or check valve from the compressor.
If the vehi-
cle will be operated in a manner where the compressor may draw in water,
the air filter should be remotely mounted in the cab with components in-
cluded with compressor.
Air Filter
Blowoff Valve
1/4” Street Tee
Drain Valve
3/8” Tube X 1/4”
MPT Connector
Reducer
Relay
15. Prepare air tank as shown. Apply pipe sealant or Teflon tape to all fittings
before tightening. .