34 Maintenance Basics – FRC

BEST PRACTICE

Factory recommended

Add grease (AquaShield

®

)

to dial ring for easier
turning.

10. Place dial ring boss onto the cam’s 90° end.

11. While keeping the 90° end in the boss and the cam in the

FRC channel, in a clockwise motion, place the dial ring onto
the FRC housing and snap into place.

12. Generously grease (AquaShield

®

) bottom of FRC housing

before placing index plate inside. Grease the top of the
index plate.

13. Place the spider with index pin assembly on the index plate.

The lifter tip should be positioned in the 1/2" gap in the
FRC channel.

NOTE

Additional information

Spread AquaShield

®

on bottom

step of ring.