CAME Axo-S7 Kit User Manual

Page 19

Advertising
background image

X 5

X 2

X 6

X 2

X 7

X 2

X 8

X 2

Pa

g.

1

9

19

-

Ma

n

u

al

c

od

e:

3

1

9

U

7

5

31

9

U

7

5

ve

r.

2

.0

2.

0

0

1/

2

0

0

9 © C

A

M

E c

an

ce

lli

auto

m

ati

ci

s.p.a. -

Th

e d

ata a

n

d i

nf

or

m

ati

on r

ep

orte

d i

n th

is

in

sta

lla

tio

n m

an

u

al

a

re s

u

sc

ep

tib

le to c

h

an

g

e at a

ny ti

m

e a

n

d w

ith

ou

t o

b

lig

ati

on

o

n C

A

M

E c

an

ce

lli

auto

m

ati

ci

s.p.a. to n

otify u

se

rs.

ENGLISH

< M1 Slow.CH % >

10

M1 Slow.CH %

< 10 >

M1 Slow.CH %

< 11 >

M1 closing deceleration%: this adjusts the (M1) first motor’s deceleration starting point before the closing endpoint.
The deceleration starting point is calculated as a percentage (from 1% to 40% of a full gate run). See illustration on page 28.
N.B.: this function appears only if it is activated in the “decel. Enc” function in the ENCODER menu.

< M2 Slow.AP % >

10

M2 Slow.AP %

< 10 >

M2 Slow.AP %

< 11 >

M2 opening deceleration%: this adjusts the (M2) second motor’s deceleration starting point before the opening endpoint.
The deceleration starting point is calculated as a percentage (from 1% to 40% of a full gate run). See illustration on page 28.
N.B.: this function appears only if it is activated in the “decel. Enc” function in the ENCODER menu.

< M2 Slow.CH % >

10

M2 Slow.CH %

< 10 >

M2 Slow.CH %

< 11 >

M2 closing deceleration %: this adjusts the (M2) second motor’s deceleration starting point before the closing endpoint.
The deceleration starting point is calculated as a percentage (from 1% to 40% of a full gate run). See illustration on page 28.
N.B.: this function appears only if it is activated in the “decel. Enc” function in the ENCODER menu.

< M1 Appr.CH % >

5

M1 Appr.CH %

< 5 >

M1 Appr.CH %

< 6 >

M1 closing acceleration %: this adjusts the (M1) first motor’s percentage rate of approach to the final closing and opening points
before reaching the opening and closing endpoints. The percentage rate of approach to (goes from 1% to 15% of the full gate run). See
illustration on page 28.

< LANGUAGE >

English

English

FUNCTIONS

FUNCTION

TIMING ADJ.

T

D

USERS

INFO

ENCODER

< LANGUAGE >

English

English

FUNCTIONS

FUNCTION

TIMING ADJ.

T

D

USERS

INFO

ENCODER

< LANGUAGE >

English

sh

FUNCTIONS

FUNCTION

TIMING ADJ.

T

D

USERS

INFO

ENCODER

< LANGUAGE >

English

English

FUNCTIONS

FUNCTION

TIMING ADJ.

T

D

USERS

INFO

ENCODER

Advertising
This manual is related to the following products: