Cashco 8310LP User Manual

Page 5

Advertising
background image

5

IOM-8310HP/LP-BASIC

A. Oversized regulator; inadequate rangeability.

A1. Check actual fl ow conditions, re-size regulator for minimum and maximum

fl ow.

A2. Decrease regulator pressure drop; decrease inlet pressure by placing a

throttling

orifi ce in inlet piping union; 2-stage pressure drop by using with

another regulator in series.

A3. Install next step higher range spring. Contact factory.

A4. Before replacing regulator, contact factory.

B. Worn plug/stem assembly; inadequate guiding.

B1. Contact factory.


Remedies

Possible Causes

1. Erratic operation; chattering.

2. Leakage through the spring chamber vent hole.

A. Normal-life diaphragm failure.

A. Replace diaphragm.

B. Abnormal short-life diaphragm failure.

B1. Can be caused by excessive chattering. See No. 1. to remedy chatter.

B2. Can be caused by corrosive action. Consider alternate diaphragm material.

B3. For composition diaphragms, assure not subjecting to over-temperature

conditions.

B4. Downstream (outlet) pressure buildup occuring that overstresses

diaphragms. Relocate regulator or protect with safety relief valve.

Remedies

Possible Causes

A. Plugged spring chamber vent.

A. Clean vent opening.

B Fluid too viscous.

B. Heat fl uid. Contact factory.

Remedies

Possible Causes

5. Sluggish operation.

A. Regulator not closing tightly.

A. Inspect trim and plug alignment.

B. Downstream block.

B. Check system; isolate (block) fl ow at regulator inlet - not outlet. Relocate

regulator

if

necessary.

C. No pressure relief protection.

C. Install safety relief valve, or rupture disc.

D. Restricted diaphragm movement.

D. Ensure no moisture in spring chamber at temperatures below freeze point.

Ensure no dust or debris entering vent opening. If rainwater or debris can

enter, re-orient spring chamber.

4. Excessive pressure downstream.

Possible Causes

Remedies

A.

Regulator

undersized.

A1.

Confi rm by opening bypass valve together with regulator.

A2.

Check

actual

fl ow conditions, re-size regulator; if regulator has inadequate

capacity, replace with larger unit.

B. Incorrect range spring (screwing in CW of adjust- B. Replace range spring with proper higher range. Contact factory.

ing screw does not allow bringing pressure level

up to proper level).

C. Too much droop.

C1. Review droop expected.

C2.

Contact

factory.

D. Restricted diaphragm movement.

D. Ensure no moisture in spring chamber at temperatures below freeze point.

Ensure no dust or debris entering vent opening. If rainwater or debris can

enter, re-orient spring chamber.

Remedies

Possible Causes

3. Downstream pressure will not reach desired setting.

SECTION VII

VII. TROUBLE SHOOTING GUIDE

Advertising