Cashco C-PRV User Manual

Page 4

Advertising
background image

IOM-C-PRV

4

Figure 2: Spring Chamber in Lock-Open Position

A. Pre-Sanitation:

1. Owner should refer to owner’s op er at ing

pro ce dures for system shutdown to include
re liev ing all system pres sure.

2. Refer to Figure 3 for item number reference ().

3. Remove the lock-open pin (10) from the pin

retainer hole in the spring cham ber (2). (See
Figure 2.)

4. System internal pressure must be at/near 0

psig (0 Barg). This will ensure plug (17) is fully
open. NOTE: Do not change range spring
(7) setting by rotating nut or handle (6).

5. Insert pin (10), jostle nut or handle (6) lift up

or push down to secure pin (10) thru ad just ing
screw (5).

B. Sanitation:

1. Flush, drain and sanitize system in ac cor dance

to owner’s spec i fi ca tions.

NOTE: Apply a small amount of Emhart
Bostic White Food Grade “NEVER-SEEZ

®

” or

equiv a lent to threads of ad just ing screw (5) .

24. Align the two ribs inside the spring chamber

(2) with the tabs (ears) on the spring button
(4) and place the spring chamber (2) over as-
sembled parts directly on body (1). Refer to
step 6 previous for alignment of match marks
for fi nal orientation.

25. Position the Tri-Clamp (13) around the mating

fl anges of the body (1) and the spring chamber
(2) with the threaded fastener aligned with
the tab slot cut in the body fl ange lip. Clamp
should be tightened to approximately 4 to 6
ft-lbs.

a.

For Opt.-80: Position the clamp (13)

halves around the mating fl anges of the body
(1) and the spring chamber (2). Insert clamp
bolts (13C), wash ers (13D) and tighten clamp
nuts (13B) in alternating pattern. The clamp
should be tightened to approximately 4 to 6
ft-lbs.

CAUTION

Owner’s cleaning solution must be com pat i ble with
regulator’s trim materials.

Figure 1: Clamp Arrangement.

NOTE: Gap be tween clamp (13A) halves should

be equal in size. See Figure 1.

26. Place nut or handle (6) onto square end of

adjusting screw assembly (5).

27. Insert hitch pin (15) through hole near the top

of the guide post (18). Apply Loctite 242 or
equivelant to set screw (27) and secure tight
into the top of the guide post (18).

28. Return to Section II. for Installation, Section

IV. for Start-up, and Sec tion VII for cleaning
procedure.

SECTION VII

VII. CLEANING PROCEDURE

NOTE: CIP is limited to 50 psig (3.45 Barg) maxi-
mum cleaning solution pres sure at 300°F (149°C).
SIP is recommended to 20 psig (1.38 Barg) sat u-
rat ed steam pressure; can withstand 30 psig (2.07
Barg), but may reduce elastomer life expectancy.

C. Post-Sanitation:

1. Prior to system start-up, remove the lock-

open pin (10) from the adjusting screw (5)
and insert it into the pin retainer hole. Unit
is again operative at the setpoint established
prior to cleaning.