Cashco B2 User Manual

Model b2, Back pressure regulator

Advertising
background image

IOM-B2

11/13

MODEL B2

BACK PRESSURE REGULATOR

The Model B2 is a back pressure regulator used to control upstream (inlet or P

1

) pressure. Sizes are 1/4" and

3/8" NPT (DN8 and DN10) FNPT or 1/2" (DN15) with Tri-Clamp connections. The unit is suitable for gaseous or
liquid service. Refer to Technical Bulletin B2-TB for design conditions and selection rec om men da tions.

SECTION II

II. INSTALLATION

1. An inlet block valve should always be installed.

2. If service application is continuous such that

shut down is not readily accomplished, it is rec-
ommended that an inlet block valve, outlet block
valve, and a manual bypass valve be installed.

3. Pipe unions should be installed to allow removal

from piping.

4. An outlet pressure gauge should be located ap-

proxi mately ten pipe diameters downstream, and
within sight.

5. All installations should include a downstream re-

lief de vice if the inlet pressure could exceed the
pres sure rating of any downstream equip ment or
the maximum outlet pressure rating of the unit.

6. Clean the pip ing of all foreign material including

chips, welding scale, oil, grease and dirt before
installing the reg u la tor. Strainers are rec om -
mend ed.

7. In plac

ing thread seal ant on pipe ends pri or to

en gage ment, ensure that excess material is re-

moved and not allowed to enter the regulator
upon startup.

8. Flow Direction: Install so the fl ow direction

match es the inlet stamp on the main regulator
body (1).

9. For best performance, install in well drained

hori zon tal pipe.

10. Basic Regulator - (Refer to Figure 2, Model B2):

Regulator may be rotated around the pipe axis
360°. Recommended position is with knob (4)
ver ti cal upwards.

11. Regulators are not to be buried un der ground.

12. For insulated piping systems, recommendation

is to not insulate regulator.

INSTALLATION, OPERATION & MAINTENANCE MANUAL (IOM)

SECTION l

I. DESCRIPTION AND SCOPE

CAUTION

This is not a safety device and must not be substituted for a code approved pressure safety relief valve or a
rupture disc.

CAUTION

Installation of adequate overpressure pro tec tion is
recommended to pro tect the reg u la tor from over-
pres sure and all down stream equip ment from dam-
age in the event of regulator failure.

Advertising