Cashco 1049 User Manual

Model 1049

Advertising
background image

InstallatIon, operatIon and MaIntenance Manual (IoM)

IoM - 1049

07-05

sectIon I

I. DESCRIPTION AND SCOPE

The Model 1049 Secure-Gard is a pilot operated vent

valve intended for installation on atmospheric and low

pressure storage tanks, vapor recovery systems, and

process systems.

Model 1049

secure-Gard pilot operated Vent Valve

WarnInG

the Model 1049 is a low pressure pilot operated valve.

In as such, does not supply vacuum relief. If vacuum

relief is required, it should be provided by a separate

device.

cautIon

Follow your company’s safety procedures to avoid in-

jury to personnel or damage to equipment.

sectIon III

III. INSTALLATION

The inlet and outlet flanges are normally standard ANSI 150 lbs. class flanges unless otherwise indicated and

should be connected following accepted piping practices.

sectIon II

II. PRIOR TO INSTALLATION

Remove all packing material inside and outside of the valve prior to installation.

saFetY WarnInG: In addition to your company’s safety procedures, this section includes guidelines that should

be followed during the installation, operation, and maintenance of Valve Concepts, Inc’s Pilot Operated Vent Valve.

It is necessary to completely read and understand these guidelines.

Tank or system over pressure protection is the primary function of pilot operated vent valves. It must be selected to

meet the total pressure flow requirements within the Maximum Allowable Working Pressure of the system on which

it is installed. Consult API Standard 2000 for tank protection sizing procedures. Improperly specified vent valves

may result in structural damage to the tank or system, and may cause severe personal injury or death.

Valves are pre-set at the factory per customer purchase specifications. DO NOT change the set pressure without

consulting the factory or your local VCI representative. Improper adjustment may cause teh valve to malfunction.

DO NOT attempt to remove the valve from the tank or process vessel without first bleeding all pressure from the

system. ALTERNATIVE MEANS OF PRESSURE VENTING MUST BE PROVIDED WHEN THE VALVE IS OUT

OF SERVICE.

The valve has been exposed to process while in service. Observe all plant procedures and Material Safety Data

Sheets (MSDS) for the products in the system while inspecting, adjusting, or servicing the valve. Take approriate

safety precautions regarding eye protection, respiration and skin contact.

Advertising