Using < 0.1 NTU StablCal Solution

Bulk solution (bottles) or sealed sample cells (vials)

This solution may be substituted for low-turbidity water when performing a
calibration using StablCal Standards.

1. Never shake or invert* this solution. Do not generate any bubbles in the

solution. Allow the solution to sit undisturbed for several minutes before use.**

2. Carefully pour the solution down the inside wall of the sample cell; this prevents

any air bubbles from forming in the sample cell.

3. Immediately cap the sample cell and the bulk solution bottle.

4. Let the filled sample cell sit undisturbed for 2 – 3 minutes.

5. The sample cell containing the solution is now ready for measurement.

REPLACEMENT PARTS AND REAGENTS

StablCal Stabilized Formazin Turbidity Standards are available in sealed sample
cells (vials) or in bulk solution (bottles). The sealed sample cells are supplied in
Calibration Sets. The bulk solution is available in individual bottles or in Calibration
Sets.

Description

Cat. No.

Cap, sample cell, Teflon lined, 12/pkg ......................................................... 24018-12

StablCal Stabilized Formazin Turbidity Standards

StablCal Bulk Solution, individual bottles:

1800 NTU, 500 mL ....................................................................................... 26607-49
1800 NTU, 100 mL ....................................................................................... 26607-42
1000 NTU, 500 mL ....................................................................................... 26606-49
1000 NTU, 100 mL ....................................................................................... 26606-42
800 NTU, 500 mL ......................................................................................... 26605-49
800 NTU, 100 mL ......................................................................................... 26605-42
200 NTU, 500 mL ......................................................................................... 26604-49
200 NTU, 100 mL ......................................................................................... 26604-42
180 NTU, 500 mL ......................................................................................... 26603-49
180 NTU, 100 mL ......................................................................................... 26603-42
100 NTU, 500 mL ......................................................................................... 26602-49
100 NTU, 100 mL ......................................................................................... 26602-42
40 NTU, 1 L .................................................................................................. 27474-53
20 NTU, 1 L .................................................................................................. 26601-53
20 NTU, 500 mL ........................................................................................... 26601-49
20 NTU, 100 mL ........................................................................................... 26601-42
18 NTU, 500 mL ........................................................................................... 26600-49
18 NTU, 100 mL ........................................................................................... 26600-42
10 NTU, 500 mL ........................................................................................... 26599-49
10 NTU, 100 mL ........................................................................................... 26599-42
1.0 NTU, 1 L ................................................................................................. 26598-53
1.0 NTU, 500 mL .......................................................................................... 26598-49

* If the solution is shaken, it can take several hours for all the bubbles to dissipate; therefore
it is recommended to refill the sample cell with fresh, unshaken < 0.1 NTU StablCal Solution.
** If the < 0.1 NTU StablCal Solution (Cat. No. 26597) has been mixed recently, wait at least 10 – 15 minutes before using.

Advertising