CUTTER MAINTENANCE (CROSS CUT):

Cross cut cutters must be oiled after a

specific operating time. If the control display

(7) comes on proceed as follows:

Open the door. The control display (8) comes on
and the reverse button (4) LED display as well

as the control display (7)

flashes. Remove the

oil reservoir (13) (Fig. 6) from the holder in the door

and close the door again.

Pour a little oil onto a sheet of paper and then

feed this through the paper feed slot (11) onto the

cutters.

The paper is drawn in and in this way the oil is

distributed to the cutters.

Note: This procedure is acknowledged as

follows to turn off the display after the cutters

have been oiled:

- Open the door until the control display (8)

lights up. The control displays (7) and (4)

flash.

7

GB

MALFUNCTIONS

MAINTENANCE / DISPOSING

TECHNICAL DATA

SPECIAL ACCESSORIES

Description

Order-No.

Plastic bag, 440x330x950x0.05 mm

99977

Lubricant, 110 ml bottle

88035

Note: For orders of special accessories and spare

parts, please contact your dealer.

fig. 5

fig. 6

Translation of the Original Operation Manual

Übersetzung der Originalbetriebsanleitung

MATERIAL JAM IN THE MACHINE:

(Auto reverse function)

If a jam is caused by too much material being fed

in the following happens:

- The cutters jam, then run in reverse for a short

time (material is released) and stop. The motor

switches off. The control display (6) comes

on.

Proceed as follows:

Paper jam in paper feed slot (11)

- Remove the paper that has been fed back.

- The cutters now run forwards automatically

and shred the remaining paper in the cutters.

During the forward run the forward button (3)
LED display comes on. The control display

(6) goes out.

- Continue shredding with less paper.

- If necessary, switch the cutters manually

alternately from forward to reverse until the

material has gone through completely and

been shredded.

LIGHT BARRIER COVERED

WHEN DOOR OPENED:

Should there still be material in the feed slot

when the door is opened, the motor switches off

and the cutters stop. The control display (6)

comes on.

Close the door and acknowledge the status

by pressing the forward button (3) briefly.

The existing material is fed to the cutters and

shredded.

LIGHT BARRIER COVERED

WHEN MACHINE TURNED ON:

Should there still be material in the feed slot

when the machine is switched on the control

display (6) comes on.

Remove the material and acknowledge the

status by pressing the forward button (3) briefly.

MOTOR PROTECTION:

Should the motor be overloaded it switches off.

The control display (9) comes on.

The machine can be started again after a cooling

down period of about 25 – 40 minutes.

ELECTRICAL FAULT:

If the control display (9)

flashes together with

the function button (2) LED display or only

the control display (8)

flashes there is an

electrical fault. The machine cannot be started.

In this case please contact your dealer.

FAULT CHECK LIST:

Should the machine not work, check the following

points:

- is the

plug connected to the power supply?

- is the

door closed?

- is the

paper collection bag full?

Follow the instructions for “EMPTYING THE

PAPER COLLECTION BAG“.

- Is there a

material jam in the machine?

Follow the instructions in “MATERIAL JAM IN

THE MACHINE”.

- Is the

motor overloaded?

See “MOTOR PROTECTION”.

If none of these test points apply, please

contact your dealer.

CLEANING THE PHOTOCELLS (Fig. 5):

If paper particles should come to rest in the inlet

guide (for example after a paper jam) it is possible

that the machine will not turn off, due to the broken

light barrier.

To remove these paper strips and also to clean

the photocell, pass another sheet of paper through

the feed slot, or switch the machine to reverse and

wipe both “eyes” of the photocell with a brush.

- Press the reverse button (4) and keep it held

down until the control display (7) goes out.

- Close the door again.

The cutters now start a cleaning cycle automatically

(forward and reverse run) and then switch off.

The machine is ready for use again. Should you

need to re-order the special oil see “SPECIAL

ACCESSORIES”.

AUTOMATIC ENERGY SAVING:

If the machine is not used for a while it automatically

switches off after about 5 minutes. The function
button (2) LED display for “Ready” goes out.

Press the function button briefly to turn it on again.

DISPOSING OF THE MACHINE:

Dispose of the machine in an

environmentally friendly fashion at the end

of its useful service life. Do not dispose of

any of the parts included in the machine or

its packaging with household waste.

* based on A4-paper 70g/m² at 230V/50Hz

Model

Typ

Cutting width

Cutting capacity

Working width Noise level

Dimensions

Weight

paper

paper

W x D x H

intimus 120SC2

227-6S

5.8 mm

35-38 sheets*

310 mm

app. 57 dB(A)

535 x 395 x 980 mm

46 kg

intimus 120SC2

227-4S

3.8 mm

31-33 sheets*

310 mm

app. 57 dB(A)

535 x 395 x 980 mm

46 kg

intimus 120CC3

227-4C

3.8x36 mm

23-25 sheets*

310 mm

app. 57 dB(A)

535 x 395 x 980 mm

47 kg

intimus 120CC4

227-2C

1.9x15 mm

15-17 sheets*

310 mm

app. 57 dB(A)

535 x 395 x 980 mm

47 kg

intimus 120CC5

227-1C

0.8x12 mm

10-12 sheets*

310 mm

app. 57 dB(A)

535 x 395 x 980 mm

47 kg

intimus 120CC6

227-1CF

0.8x4.5 mm

7-8 sheets*

310 mm

app. 57 dB(A)

535 x 395 x 980 mm

47 kg

Pre-fusing (slow-blow):

220-230V = 10 amps / 120V = 15 amps / 100V = 18 amps

Model

Power supply data

supply voltage/frequency · current consumption · power

intimus 120SC2

220-230V/50Hz · 7.8 amps · 1.8 kW

120V/60Hz · 12.0 amps · 1.4 kW

100V/50/60Hz · 18.0 amps · 1.8 kW

intimus 120SC2

220-230V/50Hz · 7.8 amps · 1.8 kW

120V/60Hz · 12.0 amps · 1.4 kW

100V/50/60Hz · 18.0 amps · 1.8 kW

intimus 120CC3

220-230V/50Hz · 7.8 amps · 1.8 kW

120V/60Hz · 12.0 amps · 1.4 kW

100V/50/60Hz · 18.0 amps · 1.8 kW

intimus 120CC4

220-230V/50Hz · 7.8 amps · 1.8 kW

120V/60Hz · 12.0 amps · 1.4 kW

100V/50/60Hz · 18.0 amps · 1.8 kW

intimus 120CC5

220-230V/50Hz · 7.8 amps · 1.8 kW

120V/60Hz · 12.0 amps · 1.4 kW

100V/50/60Hz · 18.0 amps · 1.8 kW

intimus 120CC6

220-230V/50Hz · 7.8 amps · 1.8 kW

120V/60Hz · 12.0 amps · 1.4 kW

100V/50/60Hz · 18.0 amps · 1.8 kW