7440 series, Installation instructions – KING 7440 Series PVC_PVDF User Manual

Page 3

Advertising
background image

(714) 891-0008 • www.kinginstrumentco.com

When it comes to flow...we’re instrumental.

3

Installation Instructions

Installation Instructions

7440 SERIES ASSEMBLY
PARTS LIST:

1. Frame
2. Inlet End Fitting
3. Outlet End Fitting
4. End Fitting Screw
5. O-Ring
6. Compression Screw
7. Tube Adaptor
8. Seat Bushing
9. Glass Tube Gasket
10. Float Stop

11. Float
12. Glass Meter Tube
13. Scale Plate Mount
14. Scale Plate Mount Screw
15. Scale Plate
16. Scale Plate Screw
17. Shield

7440 Series

PVC/PVDF

FRAME

O-RING

COMPRESSION SCREW

1) Inspect meter for damage that may have occurred during shipping. Report

any damage to the container to the freight carrier immediately.

This is important information. Read it carefully before

beginning work.

2) Make sure your pressure, temperature, fluid and other requirements are

compatible with the meter (including o-rings).
3) Select a suitable location for installation to prevent excess stress on the

meter which may result from:

a) Misaligned pipe.
b) The weight of related plumbing.
c) "Water Hammer" which is most likely to occur when flow is suddenly

stopped as with quick closing solenoid operated valves. (If necessary, a

surge chamber should be installed. This will also be useful in pressure

start-up situations.)
d) Thermal expansion of liquid in a stagnated or valve isolated system.

f) Instantaneous pressurization which will stress the meter and could result

in tube failure.

NOTE: In closed thermal transfer or cooling systems, install the meter in the

cool side of the line to minimize meter expansion and contraction and possible

fluid leaks at the threaded connections.

4) Handle the meter carefully during installation.

a) Use an appropriate amount of teflon tape on external pipe threads before

making connections. Do not use paste or stick type thread sealing products.

5) Install the meter vertically with the inlet port at the bottom.

GLASS TUBE GASKET

TUBE ADAPTOR

GLASS METER TUBE

SCALE PLATE

FLOAT STOP

SEAT BUSHING

MOUNT SCREW

e) It is recommended to install valving which will allow the meter to be

drained. Meter should be drained when not in use or prior to maintenance.

7) Meters used in gas service should have suitable valves plumbed in at the

inlet and outlet of the meter. These valves should be no more than 1-1/2 pipe

diameters from the meter ports. The valve at the outlet should be used to

create back pressure as required to prevent float bounce. It should be set

initially and then left alone. The inlet valve should be used for throttling

purposes. Depending on the installation, valves may not be essential, but they

are most useful in many installations. Remember: To get a correct reading of

flow in gas service, it is necessary to know the pressure right at the outlet of

the meter (before the valve).
8) Pressure and temperature maximums must never be exceeded.

BL FLOAT

SCALE PLATE MOUNT

SCALE PLATE SCREW

SCALE PLATE

SHIELD

FLOAT

2X

2X

Pressure and temperature ratings are based on a study of the engineering

data for particular materials used in construction and on the design of

individual models. This information is supplemented by destructive test

results. Meters with stainless enclosures must never be operated without

shields securely in place. Meters exposed to difficult environments such

as those created by certain chemicals, excessive vibration or other stress

inducing factors could fail at or below the suggested maximums. Never

operate meters above pressure and temperature maximums. It is strongly

recommended that all meter installations utilize an appropriate pressure

relief valve and/or rupture disc. The pressure settings and locations of

these devices should be such that meters cannot be over pressurized.

Meter failure could result in damage to equipment and serious personal

injury. Always use suitable safety gear, including OSHA approved eye

protection when working around meters in service. We are happy to pass

along chemical compatibility information that has been published by the

manufacturer's of raw materials used in our products; however, this

information should not be construed as a recommendation made by King

Instrument Company, Inc. for a specific application.

7440 meters that require repair should be sent to the factory. Please call

for a Return Merchandise Authorization (RMA) number and return

instructions.

-7440 Series meters have o-ring seals. Use with incompatible fluids may

cause o-rings to swell which may cause glass tube to fail.
-Extra caution must be exercised when meters are used in high pressure

gas cylinder applications. Pressure regulators should be installed at the

cylinder and at the inlet of the meter.
-Serious property damage and great personal injury could occur as the

result of a meter misused or used in an unsuitable application.

Carefully remove the flowmeter from the piping system. Remove the front

shield and the top frame plug. Insert a

3

16

" hex key in the outlet hole and

into the compression screw. Turn the hex key counter clockwise until the

compression screw is raised enough to be able to remove the glass tube.

Carefully remove the glass tube. Remove the compression screw by

turning the hex key clockwise. Float and float stops may be removed by

inserting a rod into one end of the glass tube and carefully pushing the

components out the other end.

All components are now fully accessible for cleaning. Components can be

cleaned with a mild soap solution. This will be an effective cleaner of rust

stains. A cotton swab may be helpful in cleaning the inside of the glass

tube. Caution must be used so that materials of construction are not

damaged by cleaning solutions. Hard water deposits can be removed with

a 5% acetic acid solution (vinegar). Before the meter is reassembled,

inspect all parts for damage. O-rings should be replaced during meter

maintenance and cleaning.

To reassemble, insert bottom float stop into glass tube and push it down

with a rod. Insert the ball float and top float stop. Install the compression

screw with the

3

16

" hex key, turning counter clockwise. Install the gaskets,

seat bushing, and tube adapters (

1

8

" float models only). Position glass

tube in frame assembly and begin to turn the compression screw

clockwise. Make sure that the tube is centered and that the reference line

is facing frontward. Tighten compression screw to 4 in. lbs. of torque.

Replace shield by snapping it into place.

Maximum Non-Shock Pressure and Temperature

200 psig

200°F

250°F

Temperature

Pressure

Gas

Liquid

Ambient

33°F - 125°F

Temperature

READ

HERE

2X

6) Meters with plastic fittings must be installed so that fittings are not made to

support any part of the associated plumbing. In addition, meter frame should

be fastened to bulkhead, panel or column.

4X

END FITTING SCREW

OUTLET END FITTING

INLET END FITTING

7/11/2013 1:50:19 PM

7440 SERIES INDUCTIVE RING SENSOR

INDUCTIVE RING SENSOR:

All 7440 Series flowmeters may be fitted with one inductive ring sensor.
The inductive ring sensor is mounted on the glass meter tube using
springs to put tension between the frame and glass meter tube.
The sensor can be either proximity or latching type and can only be
used with 316SS or Carboloy floats. The inductive ring sensor produces
an electromagnetic field that senses the metal float within sensing zone.
Inductive ring sensors are 2-wire, DC, low current devices and are de-
signed to be used with a remote intrinsic safety barrier / switch isolator.

SWITCH ISOLATOR:

Inductive ring sensors are designed to be connected to a switch isolator
for intrinsically safe applications. The purpose of the switch isolator is
to supply electrical signals between safe and hazardous areas in either
direction while limiting the amount of energy that can be transferred
even under fault conditions. Switch isolators are available with 220VAC,
110VAC or 24VDC supply voltage requirements, contain single pole
double throw (SPDT) relays, and are DIN rail mountable. See switch
isolator specifications for electrical connections and further details.

INDUCTIVE RING SENSOR
ELECTRICAL SPECIFICATIONS

TYPE:

INDUCTIVE PROXIMITY OR LATCHING

SUPPLY VOLTAGE:

5-25V DC (Switch Isolator)

OUTPUT: NAMUR
OUTPUT LOAD CURRENT:

<= 1mA-Float Present

>= 3mA (15mA Max.)-Float Absent

SWITCHING FREQUENCY: 2kHZ
HOUSING RATING:

IP67

OPERATING TEMPERATURE: -13°F to 104°F

1/8” Latching

-13°F to 158°F

1/8” Proximity

1/4” Latching

1/4” Proximity

WIRING:

PVC covered, 2 Conductor, 26

AWG, 6.5 Ft. Long. Brown (+) / Blue (-)

PEPPERL+FUCHS

UL:

General Purpose

SENSOR APPROVALS

FM:

Intrinsically Safe

CSA:

Intrinsically Safe

CENELEC: Intrinsically Safe