Start-up and operation, If using another means of chlorine, Setting control dial – King Technology POOL FROG Mineral Reservoir User Manual

Page 4: Warning

Advertising
background image

Start-up and Operation

This system is designed to work effectively with a variety of pool equipment as long as the following basic procedures are followed.

Above Ground

POOL SIZE

Gallons Diameter

8 HOUR PUMP RUN TIME

12 HOUR PUMP RUN TIME

24 HOUR PUMP RUN TIME

PUMP SIZE

1/2 hp 3/4 hp 1 hp 1 1/2 hp

PUMP SIZE

1/2 hp 3/4 hp 1 hp 1 1/2 hp

PUMP SIZE

1/2 hp 3/4 hp 1 hp 1 1/2 hp

7,000 (18’)

5.0

4.5

4.0

3.5

4.5

4.0

3.0

5.0*

3.5

3.0

2.5

4.0*

9,000 (21’)

5.5

5.0

4.5

4.0

5.0

4.5

4.0

5.5*

4.0

3.5

3.0

4.5*

12,000 (24’)

6.0

5.5

5.0

4.5

5.5

5.0

4.5

4.0

4.5

4.0

3.5

5.0*

15,000

NR

6.0

5.5

5.0

6.0

5.5

5.0

4.5

5.0

4.5

4.0

3.5

20,000

NR

NR

6.0

5.5

NR

6.0

5.5

5.0

5.5

5.0

4.5

4.0

In Ground

POOL SIZE

Gallons

6 HOUR PUMP RUN TIME

12 HOUR PUMP RUN TIME

24 HOUR PUMP RUN TIME

PUMP SIZE

3/4 hp 1 hp 1 1/2 hp 2 hp

PUMP SIZE

3/4 hp 1 hp 1 1/2 hp 2 hp

PUMP SIZE

3/4 hp 1 hp 1 1/2 hp 2 hp

7,000

4.0

3.5

3.0

3.0*

3.0

2.5

4.0*

3.5*

1.5

3.5*

3.0*

2.5*

9,000

4.5

4.0

3.5

3.0

3.5

3.0

2.5

4.0*

2.5

4.0*

3.5*

3.0*

12,000

5.0

4.5

4.0

3.5

4.0

3.5

3.0

2.5

3.0

2.5

1.5

3.5*

18,000

NR

5.0

4.5

4.0

5.0

4.0

3.5

3.0

3.5

3.0

2.5

2.0

25,000

NR

NR

5.0

4.0

NR

5.0

4.0

3.5

4.0

3.5

3.0

2.5

30,000

NR

NR

6.0

5.0

NR

5.5

5.0

4.0

4.5

4.0

3.5

3.0

35,000

NR

NR

7.0

6.0

NR

6.5

5.5

5.0

5.5

4.5

4.0

3.5

40,000

NR

NR

NR

7.0

NR

NR

6.5

5.5

6.5

5.5

4.5

4.0

* –

Bypass installation

recommended.

NR –

This pump size is not

recommended for this size pool.

24 HOUR, LOW-SPEED PUMP-RUN TIME
In order to ensure proper performance when running on low speed for 24 hours or high speed less than 6 hours, bleed the air while the pump is on by unscrewing the cap
knob until water appears. Then screw the knob back on. Repeat this process each time the cap is removed for any reason. Set the control dial at #6 and follow the adjustment
directions in Step 8 to determine the correct setting for your pool.

IMPORTANT: Pump
run times of at least 6
hours at high speed are
recommended for proper
performance. If running
low speed only or on
high speed less than
6 hours, please follow
the 24 Hour Low-Speed
directions below.

For the first week
test the pool water

daily for free chlorine with
FROG® Brand Test Strips
to ensure correct dial
setting. Continue to
test weekly throughout
the season.

Maintain setting of Maximum,
Setting 5 or ON depending on the
model. No adjustments needed.

Maintain a minimum
chlorine reading of 0.5 ppm
with a chlorine delivery device
or hand feeding.

Shock pool every two weeks or as
needed to maintain water quality.
Follow label directions on the shock
treatment used.

Shock pool every
two weeks or as

needed to maintain
water quality. Follow label
directions on the chlorine
shock treatment used.

Remember to
adjust dial by 1/2
increments only,
in order to prevent
over chlorination
which may bleach
pool surfaces.

After testing, adjust the dial up
by 1/2 increment if the free
chlorine reading has dropped
below 0.5 ppm or down by 1/2
increment if the reading has
risen above 1.0 ppm. Continue
this process each day until the
color on the test strip matches
the ideal FROG® range of 0.5
ppm to 1.0 ppm chlorine.

Set control dial by matching up the parameters of your pool on the charts below. THIS IS A STARTING POINT
ONLY and may need to be adjusted to fit your individual pool needs. See #8 for directions.

7.

Setting Control Dial

KING TECHNOLOGY, INC.
530 11th Avenue South, Hopkins, MN 55343 U.S.A.

952-933-6118 • 800-222-0169 • FAX 952-933-2206 • www.kingtechnology.com E032411553081143R7N 20-48-0168

U.S. Patents 6,210,566; 6,217,892; 6,383,507; 6,544,415; 6,551,609; 6,652,871 and

other U.S. and Foreign Patents Pending. EPA Reg. No.: 53735-11

EPA Est. No.: 071209-AZ-001

6.

7.

8.

If using another means of chlorine -

Follow steps 1-5 on Start-up and Operation and then continue below.

8.

9.

4

4

SINGLE-SPEED PUMP OR HIGH-SPEED PUMP RUN TIME

Do not add shock in or near the
skimmer or into the POOL FROG®
Cycler as it could damage equipment, risk
potential explosion or discolor your pool surface.

WARNING

Do not add shock in or near the skimmer or
into the POOL FROG® Cycler as it could damage
equipment, risk potential explosion or discolor
your pool surface.

WARNING

Advertising