Compatibility, Compliance, Compatibility compliance – ADTRAN 239 T1 HDSL4 User Manual

Page 10: Table 1, Adtran unit compatibility, Table 2, Compliance codes

Advertising
background image

4

61223445L1-5D

Description

239 H4R Installation and Maintenance Practice

Compatibility

The 239 H4R is used in conjunction with any T1.418 compliant span powering H4TU-C and H4TU-R. Compatible
ADTRAN HDSL4 transceiver units are listed in

Table 1

.

Due to span power limits, the number of H4Rs permitted in the circuit depends upon the type of H4TU-C utilized.
An ADTRAN 239 H4R provides DS1 transport on all revised resistance design (RRD) 26 AWG and/or 24 AWG
loops. Three ADTRAN 239 H4R repeaters may be added to extend the range of a loop.

Repeater placement is determined by the following criteria:

• On single H4R loops, only on the attenuation properties of the loop segment must be considered.

• For a circuit requiring two H4Rs, both segment attenuation as well as segment DC resistance requirements be

satisfied.

• For a circuit requiring three H4Rs, H4TU-C and H4TU-R hardware requirements, segment attenuation, and

segment DC resistance requirements must all be satisfied.

Refer to the

“HDSL4 Deployment Guidelines”

on page 6 of this practice and the Installation and Maintenance

Practice for the deployed H4TU-C.

Compliance

Table 2

shows the compliance codes for the 239 H4R. The 239 H4R is NRTL listed to the applicable UL standards.

The 239 H4R is to be installed in a restricted access location and in a Type “B” or “E” enclosure only.

Table 1. ADTRAN Unit Compatibility

Part Number

Unit Name

118141xLy

Total Access 3000 H4TU-C

122x401Ly

220 H4TU-C

122x403Ly

DDM+ H4TU-C

122x404Ly

3192 H4TU-C

122x407Ly

Soneplex H4TU-C

122x424Ly

T200 H4TU-R, Local Power

122x426Ly

T200 H4TU-R, Span Power

x = any generic number; y = any list number

Table 2. Compliance Codes

Code

Input

Output

Power Code (PC)

C

C

Telecommunication Code (TC)

X

Installation Code (IC)

A