2.2.3 M

OUNTING

C

ONFIGURATIONS

Ultra Series Under Pillow Block Transducers are designed for use with shafts that are mounted in Pillow Block
Bearings. See Figure 1. When choosing a mounting configuration, evaluate your options by taking the following
points into consideration:

Model type

Safety

Machine Frame orientation

Ease of Assembly

Figure 1 –Mounting Configuration



The tension-sensing roll must not be mounted where the web wrap angle can vary, or the transducer will not
interpret the tension properly. If a variance in the wrap angle occurs, it is sensed by the transducer as a tension
change and the change is indicated on the tension indicator. In cases where it is impossible to mount the transducer
where the wrap angle does not vary, the change in indicated tension that results should be calculated and if small,
can be disregarded.

Figure 2 - Example of Varying Wrap Angles

WRAP VARIES

WRAP VARIES

PROCESS

OK FOR TENSION SENSING

Pillow Block Bearing