Mating connectors, Calibration, Ating – Cleveland Motion Controls ULTRA SERIES SLIM CELL TRANSDUCER REV AA User Manual

Page 15: Onnectors, Alibration

Advertising
background image

AO-70263

R

EV

AA

U

LTRA

S

ERIES

S

LIM

C

ELL

T

RANSDUCER


P

AGE

15

OF

18

Figure 6 illustrates a typical full-bridge transducer configuration.

LEFT XDCR

8

7

6

3
4
5

2

1

1

2

3

BLK

WHT

BLU

BRN

6
5
4

8
7

WHT

BLU

BLK

BRN

1

1

2

3

4

2

3

4

RIGHT XDCR

C

T

T

C

C

T

T

C

Figure 6 – Full-Bridge Transducer Wiring

3.7 M

ATING

C

ONNECTORS

The M12 connector used on the Ultra Series Slim Cell transducer is a four-pin, DC keyed, male connector that mates
directly with the molded corsets offered by Cleveland Motion Controls. The following table lists the pin numbers
and cable colors that apply:

Pin Number

Wire Color

Signal

1 brown

Excitation

Voltage

2

white

Output – (low going)

3 blue

Excitation

Return

4

black

Output + (high going)

Figure 7 - Front View of M12 Connector

1

2

3

4

When mating the connector, align the keying mechanism and pins so that they enter the socket without you having
to apply excessive force. Use your fingers to sufficiently tighten the coupling nut enough to ensure an adequate seal
and to discourage accidental loosening.

A separate mating connector is available from Cleveland Motion Controls as a convenient field

attachable

(insulation displacement) solution if you elect to make your own cables or need to repair

damaged connectors. To order, use CMC part number, X44-34338.

3.8 C

ALIBRATION

For the proper calibration procedure, refer to the Instruction Manual that accompanied your amplifier or tension
controller.

Advertising