SECTION 5 - URC-300 MASTER CONTROLLER

Mounting
The Master Controller can be mounted in any position near the
searchlight that is protected from the weather. Check in advance that
the coax cable from the Point Pad and the wiring harness from the
searchlight can be routed to this location. Mount the Master Controller
with the wires and coax facing down. Use an appropriate fastener for
your mounting location. Use a sealant in fastener holes to prevent
moisture intrusion.

General wiring scheme

WARNING: The RCL-300 has a unique wiring scheme. Special

attention must be paid to the following chart.

The Master Controller is supplied with an in-line fuse-holder on the
Orange power lead. Use only 30 amp fuses in this fuse-holder. See
chart below for the Master Controller wiring diagram.

WARNING: Failure to follow this arrangement may damage

components.

Table 1

WARNING: This wire MUST be fused with a 30 amp fuse in the

Master Controller's in-line fuse-holder.

Master

Controller

Wire

Searchlight

Cable Wire

Wire Gauge

(AWG)

Power Source

Lead

Function

Orange

16

+12 VDC or

+24 VDC**

URC-300 Power

Blue

16

Ground

URC-300

Ground

Yellow

Yellow

16

Position Sensor

Signal

Green

Green

16

Position Sensor

Common

Red

Red

16

Up

White

White

16

Down

Black

Black

16

Right

Brown

Brown

16

Left

White

White

12

Lamp Power

Black

Black

12

Lamp Ground