Andrew ATC200-Lite User Manual

Page 7

Advertising
background image

ATC200-Lite Teletilt

®

Remote Control Downtilt System

Bulletin 639510

May 2005

v

5. Always avoid unnecessary movement of body, such as scuffing feet across flooring, when

handling ESDS equipment. Such movement will generate additional charges of static

electricity.

6. When removing or replacing ESDS equipment, hold the device or assembly through the

electrostatic-free wrap, where possible. If this is not possible, lift the device or assembly

by its body only. Do not touch component leads, connector pins, or any other electrical

connections or paths, even though they are covered by conformal coating.

7. Do not allow ESDS equipment to come in contact with clothing or other ungrounded

materials that may have an electrostatic charge. Charges on nonconductive material are

not equal. For instance, a plastic storage bag may have a - 10,000 volt potential 1/2 inch

from a +15,000 volt potential with many such charges all over the bag. Do not hand ESD

equipment to another person until it is safely packaged for protection for ESD.

8. When moving ESDS equipment, always touch the surface on which it rests with bare skin

for at least one second before lifting. Before setting it on any surface, touch the surface

with your free hand for at least one second. Contact with the bare skin provides a safe

discharge path for charges accumulated while you are moving around.

9. While servicing equipment containing ESD devices, do not handle or touch materials such

as plastic, vinyl, synthetic textiles, polished wood, fiberglass, or similar items that can

generate static charges; unless you repeat the grounding process with the bare hands

after contacting these materials.

10. Where possible, avoid repairs that require soldering at the equipment level. Soldering

irons must have heater/tips assemblies that are grounded to an electrical ground. Do not

use standard plastic solder suckers (special antistatic solder suckers are commercially

available).

11. Ground the leads of test equipment momentarily before you energize the test equipment

and before you probe ESD devices or assemblies.

12. Work benches used for setting ESDS equipment should have ESD protective work sur-

faces. These work benches should also have personnel ground straps. These straps

prevent discharge of static electricity from personnel handling ESDS items on the work

bench surface. The work bench surface should be connected to ground through a ground

cable. The resistance in the bench top ground cable should be located at or near the point

of contact with the top of the work bench. The resistance should be high enough to limit

any leakage current to 5 milliamperes or less. This takes into consideration the highest

voltage source within reach of grounded people and all the parallel resistances to ground,

such as wrist ground straps, table tops, and conductive flooring.