Ii - performances – Continental Industrie Model - 700 User Manual
Page 4

Values, dimensions and reference in this brochure are approximate and intended as guide only, not for construction and are subject to change without notice
DETAILED ENGINEERING DESCRIPTION - CONTINENTAL INDUSTRIE
DEB700EN – 04/2010
4/4
<
13.0 Recommended maximum allowable piping forces and moments on blower
connections
13.1 Inlet flange
FX = 140 KG
FY = 370 Kg
FZ = 290 Kg
MX = 180 kgm
MY = 90 kgm
MZ = 90 kgm
13.2
Outlet flange
FX = 120 kg
FY = 300 kg
FZ = 240 Kg
MX = 180 kgm
MY = 90 kgm
MZ = 90 kgm
where :
F = force
M = moment
X = Axial - parallel to rotor centre line
Y = Vertical
Z = Horizontal - normal to rotor centre line.
14.0 Vibration and noise
Vibration tolerance: 4,5 mm/s RMS
Vibration shall not exceed 4,5 mm/s RMS when measured in the vertical plane at the
bearing housings with the blower operating at the design speed.
Sound level: please refer to the calculation data sheet
II - PERFORMANCES
1.
All tests if required are in conformity with ASME Power Test Code.
2.
For constant speed blowers:
- The head shall be within the range of 100% - 105% of the normal head at design capacity,
- The horsepower based on measured head shall not exceed 107% of the value at the specified
normal operating point.
3.
For variable speed machines:
- through the rotational speed, the head shall be adjusted as close as possible to the design point,
with zero negative tolerance,
- the horsepower at that point shall not exceed 104% of the predicted shaft power value.