CONTREX CX-1102 User Manual
Page 12

Page 10
Step 1 - Application Configuration - Parameter Entry
Close the "Setup" input. The CX-1102 will change to "Setup State" and will automatically display
System Setup Application\Page 1. Setup State {MP-59} will equal 0.
Configure the CP’s on this screen as required.
System State {MP-50}
Setup State {MP-59}
App Select {CP-202}
UnitPrs Sel {CP-208}
Time Base {CP-209}
FixedDiaSel {CP-207}
UwndDiaPrst {CP-364}
WindDiaPrst {CP-365}
NOTE: The Help key accesses the Help screen and gives you a brief description of the parameter or
subject that is highlighted (active) on the screen. Press the Help key again to return to the previous screen.
Press the "Page Down" key to proceed to the next step.
Step 2 - Axis Configuration - Parameter Entry
The CX-1102 will display System Setup Axis Configuration\Page 2.
Setup State {MP-59} will equal 1 (not displayed on this screen).
Configure the CP’s on this screen as required.
WindCO Mode {CP-285}
WindCO MaxVolts {CP-286}
Wind PPR {CP-266}
WindGearRdcn {CP-265}
Wind MaxRPM {CP-329}
UwndCO Mode {CP-280}
UwndCO MaxVolts {CP-281}
Unwind PPR {CP-261}
UwndGearRdcn {CP-260}
Uwnd MaxRPM {CP-329}
NOTE: The Help key accesses the Help screen and gives you a brief description of the parameter or
subject that is highlighted (active) on the screen. Press the Help key again to return to the previous screen.
Press the "Page Down" key to proceed to the next step.