CONGRATULATIONS

Congratulations on purchasing your new CTEK professional 24 V DC/DC switch mode battery

charger, 12 V converter and battery equalizer. This charger is part of a range of professional bat-

tery chargers from CTEK SWEDEN AB. It represents the latest technology in battery charging with

charging and analysis in 4 steps with temperature compensation.

Read this User Manual and follow the instructions carefully before using your new charger.

SAFETY

•



The charger is designed for 24 V lead-acid batteries mounted into vehicles.

Do not use the charger for any other purpose

•



Use safety glasses when connecting or disconnecting a battery.

•



Battery acid is corrosive. Rinse immediately with water if acid comes into contact with skin

or eyes. Seek medical advice.

•



Make sure that the cables are not being pinched or in contact with warm surfaces

or sharp edges.

•



While charging, a battery can emit explosive gases, avoid sparks in the immediate area.

•



Always provide for proper ventilation during charging.

•



Avoid covering the charger.

Starter Battery

24 V+

Service Battery

24 V+

Service ground

Service Battery Midpoint

D250TS

The D250TS has one 24 V input and two alternating outputs. One output charge a 24 V

battery and the other provides 50 % of the input voltage to the midpoint of a 24 V system. This

enables connection of 12 V consumers to the battery string and also equalizing this battery

string, for longer battery life.

D250TS

FEATURES:

•



Multi-step10 A temperature compensated battery charging and battery maintenance.

• Battery separation of Starter and Service batteries.

• Equalization of Service batteries

• Makes connection of 12 V consumers directly to 24 V Service battery possible.

• When the charger is correctly connected the charger will output 24 V on the status signal wire.

Connection of a 24 V lamp (max 2 W) to the status signal wire will indicate a correctly con-

nected charger.

• The charger will maintain the starter battery untill the supply is below 14V. To avoid draining the

service battery always connect a charger to the service battery when the vehicle is not used for

a longer period.

+IN

+OUT

EQU

D250TS

Status signal wire

Temperature sensor

20015884C D250TS, Manual, Print file 002.indd 3